Inspection
Inspection Details
Equipment ID
23433
23433
Inspection Date
1/15/2020
1/15/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
Drew Reams
Drew Reams
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
4d35fd5e-3a53-472d-97be-bf43b07883ae
4d35fd5e-3a53-472d-97be-bf43b07883ae
Location
Progressive Ozark Bank
904 W SCENIC RIVERS BLVD, SALEM, MO
Phone: (573) 729-4146
904 W SCENIC RIVERS BLVD, SALEM, MO
Phone: (573) 729-4146
Owner
Attn: Susan
Progressive Ozark Bank
904 W SCENIC RIVERS BLVD, SALEM, MO 65560
Phone: (573) 453-2423
Email: smpryor@progressiveozarkbank.com
Progressive Ozark Bank
904 W SCENIC RIVERS BLVD, SALEM, MO 65560
Phone: (573) 453-2423
Email: smpryor@progressiveozarkbank.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | No | No | Only items relating to the operation of the elevator shall be stored in the machine room. All non-elevator related materials shall be removed from the machine room. | 5/13/2019 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Emergency lighting shall work. | 5/13/2019 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm shall work. | 3/20/2019 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | A ABC type fire extinguisher shall be provided in the machine room. | 5/13/2019 |
| A17.1-1996 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 1001.2(e)10 | Yes | No | A Category 5 full load test shall be witnessed. | 3/20/2019 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1001.2(d)(12) - | No | No | "Do not use in case of fire" signage is required. | 5/13/2019 |
| A17.1-1996 : Elevators | 4.2 - Hoistway doors | 1001.2(d)(2) | No | No | The distance between the inside face of the hoistway door and the edge of the landing sill shall be less than 3". | 5/13/2019 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A variance shall be requested to allow a residential elevator to be installed in a commercial application. | 5/13/2019 |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 1001.2(c)(18) | No | No | All hoistway wiring shall be enclosed in conduit. | 5/13/2019 |
| A17.1-1996 : Elevators | 3.14 - Hoistway clearances | 1001.2(c)(20) | Yes | No | Complete fascia is required to maintain proper car clearances. | 7/9/2019 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Emergency light shall work. | 5/13/2019 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | A pit light switch is required. | 5/13/2019 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Emergency light failed to operate during test. | 3/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | Yes | Phone, emergency bell and emergency light failed to operate. Elevator was red tagged power shut off at disconnect. Email sent to office. | 12/19/2022 |