Inspection
Inspection Details
Equipment ID
2047
2047
Inspection Date
1/23/2020
1/23/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
Christopher Hughes
Christopher Hughes
Relief Valve Pressure
400
400
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
574911b2-57de-41ff-b749-6d61ffc6b7fb
574911b2-57de-41ff-b749-6d61ffc6b7fb
Location
Lee's Summit High School
400 SE BLUE PKWY, LEES SUMMIT, MO
Phone: (816) 986-2000
400 SE BLUE PKWY, LEES SUMMIT, MO
Phone: (816) 986-2000
Owner
Attn: Lee's Summit R-7 School District
Lee's Summit R-7 School District
502 TRANSPORT DR, LEES SUMMIT, MO 64081
Phone: (816) 986-2181
Email: matthew.tillman@lsr7.net
Lee's Summit R-7 School District
502 TRANSPORT DR, LEES SUMMIT, MO 64081
Phone: (816) 986-2181
Email: matthew.tillman@lsr7.net
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Overhead lighting in car inadequate, and unguarded. | |||
MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | x | Emergency phone not identifying location of call. | 1/19/2021 | |
MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | x | Emergency lights not working. | 1/19/2021 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Emergency phone not identifying the location. | 1/19/2022 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working, alarm bell ok. | 1/19/2023 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate in machine room. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | Connection loose on controller starter box din rail. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | Fire service testing log not up to date. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | Provide covers for FFS modules in machine room. | |||
A17.1-2016 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | Machine room door must be self-closing | |||
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone not being answered | 4/1/2024 | |
A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | Shunt trip not overriding battery lowering. Need relay added | 4/1/2024 | |
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.4.19.6 | x | Top hoistway smoke sensor recalls elevator to wrong floor. Need relay added | 4/1/2024 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working, alarm bell ok. |