Inspection
Inspection Details
Equipment ID
9898
9898
Inspection Date
1/29/2020
1/29/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Dennis Drinkard
Dennis Drinkard
Mechanic Name
Michael Elder
Michael Elder
Relief Valve Pressure
Slide
14
14
Governor Rope Pull
680
680
Door Closing Force
20
20
External ID
fbf77d09-bf54-42a3-9728-bc47f55a043b
fbf77d09-bf54-42a3-9728-bc47f55a043b
Location
IREC Bldg-
1509 W TRUMAN RD, INDEPENDENCE, MO
Phone: (816) 521-5320
1509 W TRUMAN RD, INDEPENDENCE, MO
Phone: (816) 521-5320
Owner
Attn: Independence School District
Independence School District
201 N FOREST AVE, INDEPENDENCE, MO 64055
Phone: (816) 521-5330 Ext: 61007
Email: Geri_frink@isdschools.org
Independence School District
201 N FOREST AVE, INDEPENDENCE, MO 64055
Phone: (816) 521-5330 Ext: 61007
Email: Geri_frink@isdschools.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Adjust relating on two speed hoistway doors to get a minimum of 1/2 inch overlap on the landing marked "1", currently there is less than that in overlap creating a pinch hazzard | 3/12/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Provide Maintenance Records Log | 3/12/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | The Maintenance Control Program (MCP) On-Site documents are not in the machine room. | 1/3/2022 | ||
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | The firefighters service test log is not being filled out monthly. | 1/3/2022 | ||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | replace burnt out pit light bulbs | 1/3/2022 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | Could not find Maintenance Control Program (MCP) documents in the machine room | 10/27/2025 | ||
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | the fire service test log in the machine room is not being filled out monthly | 10/27/2025 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | 1st floor hoistway door closer needs to be adjusted, will not self close last two inches | 10/27/2025 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | 3rd floor hoistway door closer needs to be adjusted, will not self close last two inches | 10/27/2025 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Repair machine room lights that are not working, required to have all the light fixtures working above the running equipment | 10/27/2025 | ||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Replace missing pit light bulb | 10/27/2025 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | x | Repair machine room lights that are not working, required to have all the light fixtures working above the running equipment. repeat violation | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | x | x | the brake stopped the rotation of the drive sheave and the Ropes slid over the drive sheave during the 125% brake test. Elevator slid onto the final limit, elevator red tagged until passes 125% test. Counterweight balance is around 35% Item 2.27.2.1(1) |