Inspection
Inspection Details
Equipment ID
15929
15929
Inspection Date
2/6/2020
2/6/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
Slide
5 1/2"
5 1/2"
Governor Rope Pull
150/410
150/410
Door Closing Force
20/22
20/22
External ID
34a314fa-1f27-466a-b09f-84fb57c98363
34a314fa-1f27-466a-b09f-84fb57c98363
Location
St. Louis Old Post Office
815 OLIVE ST, SAINT LOUIS, MO
Phone: (314) 543-0101
815 OLIVE ST, SAINT LOUIS, MO
Phone: (314) 543-0101
Owner
Attn: St. Louis US Custom House & Post Office
St. Louis US Custom House & Post Office
815 OLIVE ST, SAINT LOUIS, MO 63101
Phone: (314) 994-4444
Email: amartin@descogroup.com
St. Louis US Custom House & Post Office
815 OLIVE ST, SAINT LOUIS, MO 63101
Phone: (314) 994-4444
Email: amartin@descogroup.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | Fasten loose sill plate in elevator cab at front opening. | 3/18/2026 | ||
| A17.1-1996 : Elevators | 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing | 1206.2(c) | Clean elevator car top. | 3/18/2026 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State Elevator Certificate. | 3/18/2026 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | Car sills are loose, repair as needed. | 3/18/2026 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | Clean the car top. | 3/18/2026 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | Clean the pit. | 3/18/2026 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Controller cooling fan has bad bearing, repair as needed. | 3/18/2026 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Provide existing emergency lights to work, bell was ok. | 3/18/2026 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Sump pump in pit is not plugged in, determine if it works. If not, replace. | 3/18/2026 | ||
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | Provide testing of the elevator on emergency power. | 3/18/2026 | |
| A17.1-2016 : Elevators | 4.12 - Standby power selection switch | 8.6.4.19.7 (Re-Inspection) | x | Provide testing of the elevator emergency power selector switch, located in the Fire Control Room. | 2/18/2026 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State Elevator Certificate. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Test incomplete, need to test elevator on emergency power & emergency power selector switch, located in the fire control room. Re-inspection required | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | Car sills are loose, repair as needed. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Controller cooling fan has bad bearing, repair as needed. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | Clean the pit. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | Clean the car top | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Provide existing emergency lights to work, bell was ok. Re-inspection required | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Sump pump in pit is not plugged in, determine if it works. If not, replace. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Elevator was down for parts, need to test elevator. Re-inspection required |