Inspection
Inspection Details
Equipment ID
10906
10906
Inspection Date
2/11/2020
2/11/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
John Hambrough
John Hambrough
Relief Valve Pressure
510
510
Slide
Governor Rope Pull
Door Closing Force
NA
NA
External ID
7d99d7bc-c5b3-4ea4-8f76-53c37de20471
7d99d7bc-c5b3-4ea4-8f76-53c37de20471
Location
Extra Space Storage
4210 FOREST PARK AVE, SAINT LOUIS, MO
Phone: (314) 502-2561
4210 FOREST PARK AVE, SAINT LOUIS, MO
Phone: (314) 502-2561
Owner
Extra Space Development LLC
2795 E COTTONWOOD PKWY STE 400, SALT LAKE CITY, UT 84121-7033
2795 E COTTONWOOD PKWY STE 400, SALT LAKE CITY, UT 84121-7033
Billing
Attn: Extra Space Development LLC
2795 E COTTONWOOD PKWY STE 400, SALT LAKE CITY, UT 84121-7033
2795 E COTTONWOOD PKWY STE 400, SALT LAKE CITY, UT 84121-7033
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Rooms and Machinery Spaces | No | No | Remove materials from machine room that do not involve elevator operation. | 4/27/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean pit. | 2/20/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | No | No | Provide feeder location on main line disconnect. | 2/20/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | No | No | Provide feeder location on the 110v. disconnect. Also other disconnects next to it. | 2/20/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 3.18 | No | No | Remove scavenger unit from pit. | 2/20/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 3.18 | No | No | Remove scavenger line from tank. | 2/20/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 3.18 | No | No | Provide pit bucket. | 2/20/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | There is a oil recovery unit installed in the pit of this elevator designed to return the oil leakage from the packing gland on the cylinder head. The State of Missouri has determined that this device does not suffice for oil leakage and is only allowed for temporary use until the packing gland can be repaired/replaced. Remove the recovery unit after the packing gland has been repaired/replaced and record the oil loss per A17.1 2016 - 8.6.5.5.7 | 2/20/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | This elevator has an overspeed valve device installed that is not sealed and is now required to have a 5 year full load test performed. This requirement is due to the State of Missouri adopting the A17.1 2016 version of the elevator safety code. Overspeed valve shall be tested on or before the next annual inspection. | 3/18/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | No | No | Provide feeder location on main line disconnect. The main disconnect shall have directions to the location of where the main line power supply is for emergency purposes. | 2/20/2026 |
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | Yes | No | Over speed valve is not sealed and shall be tested within 14 days. This test shall be done every 5 years from the original testing date. | 4/3/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | Yes | No | OSV testing required. | 2/20/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7.1.3 Provide Auxiliary Lighting | Yes | No | Auxiliary lighting is inoperable and shall be repaired or replaced. |