Inspection
Inspection Details
Equipment ID
5749
5749
Inspection Date
2/13/2020
2/13/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Bailey
Michael Bailey
Mechanic Name
Marcus Geno
Marcus Geno
Relief Valve Pressure
760
760
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
22
22
External ID
b7122e0d-901d-4eba-b99c-af7144b79d83
b7122e0d-901d-4eba-b99c-af7144b79d83
Location
Midtown, LLC
3010 LOCUST ST # 3016, SAINT LOUIS, MO
Phone: (314) 652-0800
3010 LOCUST ST # 3016, SAINT LOUIS, MO
Phone: (314) 652-0800
Owner
Attn: Midtown Property, LLC
Midtown Property, LLC
3010 Locust ST STE 100, ST. LOUIS, MO 63103
Phone: (314) 305-6609
Email: becky@toky.com
Midtown Property, LLC
3010 Locust ST STE 100, ST. LOUIS, MO 63103
Phone: (314) 305-6609
Email: becky@toky.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 8.6.5.16.5 | No | No | Unsealed | 3/31/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Not working,repair as needed. | 4/10/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Overhead governor shall be tested for proper setting of safeties. Unable to test with one person. | 8/15/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.1.6(h) Phase 2 Audible/Visual Signal (Re-Inspection) | Yes | No | Lobby fire hat does not illuminate on phase 1 recall. | 8/15/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work. Phone does not work without 110v. | 8/15/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Spaces containing machines, control equipment, sheaves, and other machinery shall be separated from the remainder of the building by fire-resistive enclosure. | 5/27/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/27/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)9 Capacity Plate | No | No | Replace missing in-car capacity plate. | 5/27/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work. Phone does not work when 110v circuit to car is disconnected. This violation was originally cited on 4/19/24 and still not corrected as of 8/15/24. This shall be corrected within 14 days or unit will be red tagged and placed out of service until corrected. | 10/3/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Relief valve pressure test shall be completed. Mechanic did not have proper gauge attachment to connect. | 5/1/2025 |