Inspection
Inspection Details
Equipment ID
17797
17797
Inspection Date
3/3/2020
3/3/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Jeffrey VanZant
Jeffrey VanZant
Relief Valve Pressure
460
460
Slide
Governor Rope Pull
Door Closing Force
FR 23 R 25
FR 23 R 25
External ID
c6374898-6585-47f6-aada-03f0fbf5d696
c6374898-6585-47f6-aada-03f0fbf5d696
Location
O'Reilly Barnes Warehouse
230 S BARNES AVE, SPRINGFIELD, MO
Phone: (417) 829-5772
230 S BARNES AVE, SPRINGFIELD, MO
Phone: (417) 829-5772
Owner
O'Reilly Automotive
233 S PATTERSON AVE, SPRINGFIELD, MO 65802-2210
233 S PATTERSON AVE, SPRINGFIELD, MO 65802-2210
Billing
Attn: O'Reilly Automotive
233 S PATTERSON AVE, SPRINGFIELD, MO 65802-2210
233 S PATTERSON AVE, SPRINGFIELD, MO 65802-2210
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall give proper location message, ( no Location message given) | 5/5/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Front and Rear Car Door restrictor shall work. | 5/5/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | G(1). Battery Lowering shall work. Repair or replace. | 7/1/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall give proper location message, ( no Location message given) | 5/5/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Front and Rear Car Door restrictor shall work. | 5/5/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | G(1). Battery Lowering shall work. Repair or replace. | 5/5/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | G(1)/A17.1-2016:8.6.1.4 :Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil loss log and Fire service testing log, recorded monthly. | 4/26/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Car Door restrictor shall work. | 5/4/2022 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.3a(8) Visual and audible signal | Yes | No | Must Make Fire Service Visual Signal Operable 2.27.3.1.6(h) | 4/14/2023 |
| A17.1-2016 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.5.2 Collection of Oil Leakage | No | No | Must povide means to monitor oil loss from jack Packing Glands. (currently overflow tubes routed back to power unit.) 8.6.5.5.2 | 4/11/2023 |