Inspection
Inspection Details
Equipment ID
2886
2886
Inspection Date
5/24/2018
5/24/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Relief Valve Pressure
Na
Na
Slide
NA
NA
Governor Rope Pull
NA/Na
NA/Na
Door Closing Force
NA
NA
External ID
2886
2886
Location
Gasconade Pump Station P-115
4105 South 1st St, St. Louis, MO
Phone: (636) 768-6200
4105 South 1st St, St. Louis, MO
Phone: (636) 768-6200
Owner
Metropolitan Sewer District STL
2350 Market St, St. Louis, MO 63103-2555
2350 Market St, St. Louis, MO 63103-2555
Billing
Attn: Metropolitan Sewer District
Accounts Payable
2350 Market St, , MO 63103-2555
Accounts Payable
2350 Market St, , MO 63103-2555
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Emergency phone not working | 10/15/2020 |
| conversion | conversion | n/a | No | No | Post MO operating certificate in machine room | 10/15/2020 |
| conversion | conversion | n/a | No | No | Need maintenance control program | 10/15/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Provide protection for cab lighting. | 10/15/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency phone. | 4/30/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current certificate in machine room. | 10/15/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)2 | No | No | Secure cab panel to platform. | 10/15/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | Replace missing gate latches at 1st and 2nd landings. | 10/15/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Repair gate restrictor for proper operation. | 10/15/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | Emergency phone line must call and be received by a 24 hour service line. | 10/16/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)6 | No | Yes | The current hoistway door interlock does not prevent the door from being opened when the car is away from the landing. The door shall be provided with approved interlocks. | 10/16/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)9 | Yes | Yes | The hoistway gate must be at least 7 feet high at each landing sill. | 10/16/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | The Current operating certificate shall be posted in the machine room in a non combustible frame | 10/15/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | There shall be maintenance records in the elevator machine room or accessible to the inspector. Shall consist of maintenance task such as callbacks, examinations, test, adjustments, and replacements | 10/15/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)9 | Yes | Yes | Gates must have interlocks and be at least 7" high at each landing. Red tagged elevator. |