Inspection
Inspection Details
Equipment ID
11798
11798
Inspection Date
3/23/2020
3/23/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Richard Rickermann
Richard Rickermann
Relief Valve Pressure
200/520
200/520
Slide
Governor Rope Pull
Door Closing Force
16
16
External ID
7f688438-361d-4b5a-b3be-936428b7705b
7f688438-361d-4b5a-b3be-936428b7705b
Location
West County Community Church
17770 MUELLER RD, WILDWOOD, MO
Phone: (636) 230-8900
17770 MUELLER RD, WILDWOOD, MO
Phone: (636) 230-8900
Owner
Attn: Fellowship of Wildwood
Fellowship of Wildwood
17770 MUELLER RD, WILDWOOD, MO 63038
Phone: (636) 324-7175
Email: alissa@fellowshipofwildwood.org
Fellowship of Wildwood
17770 MUELLER RD, WILDWOOD, MO 63038
Phone: (636) 324-7175
Email: alissa@fellowshipofwildwood.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone not working, maybe no phone line | 6/4/2020 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 3/8/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/8/2023 |
| A17.1-1996 : Elevators | 2.14 - Code data plate | 1200.6 | No | No | The code data plate required by A17.1 2016, Section 8.9, shall be provided in plain view, securely attached to each main line disconnect or controller. | 3/8/2023 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1001.2(a)(17) | Yes | No | The emergency lowering device (ERU) shall be operational. | 3/7/2022 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | 3/8/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/17/2022 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | There is oil in the pit. Clean the pit and correct source of oil leak. | 5/30/2024 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | Yes | No | Car door does not automatically close when fire operation is turned off. | 5/30/2024 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Oil shall not be allowed to accumulate on pit floor. Oil on the pit floor shall be removed. | 4/24/2025 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | Fire service testing shall be documented monthly. | 5/21/2025 |
| A17.1-1996 : Elevators | 1.7 - Car door or gate | 204.4 | Yes | No | Door restrictor shall work. |