Inspection
Inspection Details
Equipment ID
15442
15442
Inspection Date
2/19/2020
2/19/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
Benjamin Williams
Benjamin Williams
Relief Valve Pressure
Slide
15.5" @ 200 FPM
15.5" @ 200 FPM
Governor Rope Pull
170/NA
170/NA
Door Closing Force
15
15
External ID
b3b8159c-5d7c-4f63-bd45-a689cb75134f
b3b8159c-5d7c-4f63-bd45-a689cb75134f
Location
Park Lane Apartments
4907 W PINE BLVD, SAINT LOUIS, MO
Phone: (314) 304-3747
4907 W PINE BLVD, SAINT LOUIS, MO
Phone: (314) 304-3747
Owner
Asprient Properties LLC
1204 DUNSTON DR, SAINT LOUIS, MO 63146-5685
1204 DUNSTON DR, SAINT LOUIS, MO 63146-5685
Billing
Attn: Asprient Properties LLC
1204 DUNSTON DR, SAINT LOUIS, MO 63146-5685
1204 DUNSTON DR, SAINT LOUIS, MO 63146-5685
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Install proper emergency exit cover. Must be designed to support weight and secured so that it can only be opened from the car top without the use of tools. | 12/12/2018 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | Yes | Yes | Test the car safeties and provides means (tool) to wind up safeties for testing. | 2/19/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)9 Capacity Plate | No | No | Provide means for substantially level floor. Pull out hole creates a tripping hazard. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self-locking and self-closing. | 9/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Provide a current tested fire extinguisher in the machine room. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Wooden stairway treads to access machine and controller are worn and damaged and shall be replaced or repaired as needed. | 9/15/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 9/15/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | Emergency exit is not code compliant. | 9/15/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit light shall work. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide code compliant lighting in the machine room (10 FTC minimum). | 9/15/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | The governor rope pullout shall be 42" or less. | 9/7/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The debris in the pit shall be removed. The pit shall be kept clean. | 9/15/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit lighting shall be operational. | 9/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | The car safety key shall be kept on-site. | 9/15/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | The emergency exit shall be capable of sustaining a load of 300 lbs. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all material from the machine room which is not required for the operation of maintenance of the elevator. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | The wooden steps going up to the machine room deck are damaged and shall be replaced. | 9/15/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | The exposed wiring on the car top and in the hoistway at the 2nd landing shall be enclosed. | 9/15/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | All wireway and electrical device covers must be installed. | 9/15/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 9/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide a current tested ABC fire extinguisher in the machine room. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide a minimum of 10 ft candles of illumination measured at the floor through out the machine room | 9/27/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Remove exposed wiring and splices from car top and replace with proper NEC wiring | 9/27/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide MCP. | 6/1/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 6/1/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Provide existing pit light to work. | 6/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Provide safe and convenient access to the elevator machine room, wooden steps leading in are damaged. | 6/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | First plank into the machine room needs to be secured down. Trip hazard. | 6/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self locking / self closing | 7/1/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Electrical wiring provided for new cab lighting shall be protected & open splices enclosed in junction boxes per NFPA 70 | 7/1/2024 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Provide a current tested ABC fire extinguisher in the machine room. | |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Exposed wiring and splices on cartop need to be enclosed per NEC. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Car would not pick load. Safeties were not set. Need to return when repairs have been made to set safeties to complete 5 year test. |