Inspection
Inspection Details
Equipment ID
15072
15072
Inspection Date
2/20/2020
2/20/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Gregory Sacks
Gregory Sacks
Mechanic Name
Charles Sheriff
Charles Sheriff
Relief Valve Pressure
NA
NA
Slide
Governor Rope Pull
Door Closing Force
NA
NA
External ID
b0d69dc3-9fad-46c9-ae93-5be585ef2073
b0d69dc3-9fad-46c9-ae93-5be585ef2073
Location
Social science Bldg
4601 MID RIVERS MALL DR, SAINT PETERS, MO
Phone: (636) 922-8454
4601 MID RIVERS MALL DR, SAINT PETERS, MO
Phone: (636) 922-8454
Owner
Attn: St. Charles Community College
St. Charles Community College
4601 MID RIVERS MALL DR, SAINT PETERS, MO 63376
Phone: (636) 922-8493
Email: kbray@stchas.edu
St. Charles Community College
4601 MID RIVERS MALL DR, SAINT PETERS, MO 63376
Phone: (636) 922-8493
Email: kbray@stchas.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| Missouri Minimum : Platform Lifts | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Display current state operating certificate. | 12/16/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | Emergency light and alarm shall be operational. | 12/9/2020 |
| Missouri Minimum : Platform Lifts | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Display a current MO state operating certificate on or near the lift. | 12/16/2025 |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | Yes | No | Alarm bell shall work with loss of main 120v power. | 12/5/2024 |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | Yes | No | Emergency lighting shall work. | 12/5/2024 |
| Missouri Minimum : Platform Lifts | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | A current MO State operating certificate shall be posted near the equipment, in a noncombustible frame with a clear protective vision plate over it. | 12/16/2025 |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | Yes | No | Emergency lighting shall be operational. (2nd Notice) | 12/16/2025 |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | No | No | Unit is due for category 5 test in 2025. | 12/16/2025 |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | Yes | No | Lift must operate from all lanidngs and platforms by switches located at the stations. | |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | Yes | No | Emergency light still not operational. | |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | Yes | No | Category 5 full load testing is due. |