Inspection
Inspection Details
Equipment ID
12214
12214
Inspection Date
3/20/2020
3/20/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
28
28
External ID
5f3e1857-e979-4277-aa1e-21d411845c6d
5f3e1857-e979-4277-aa1e-21d411845c6d
Location
The St. Louis Club
7701 FORSYTH BLVD, SAINT LOUIS, MO
Phone: (314) 795-7797
7701 FORSYTH BLVD, SAINT LOUIS, MO
Phone: (314) 795-7797
Owner
Attn: UNK
The St. Louis Club
7701 FORSYTH BLVD, CLAYTON, MO 63105
Phone: (314) 862-2432
Email: d_kasten@commonwealth.com
The St. Louis Club
7701 FORSYTH BLVD, CLAYTON, MO 63105
Phone: (314) 862-2432
Email: d_kasten@commonwealth.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 3.23 - Suspension rope | 206.7 | Yes | Yes | Suspension ropes need replacement. Red tagged unit. | 3/20/2020 |
| A17.1-1996 : Elevators | 3.26 - Broken rope, chain, or tape switch | 1001.2(c)(9) | Yes | No | Repair safety switch on counterweight safety | 3/20/2020 |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 1001.2(c)(18) | No | No | Install cover on open electric box at 2nd floor in hoistway and missing duct cover at top hoistway. | 6/1/2020 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.8 Switch Keys | No | No | Replace mislabeled Phase I fire service key switch. | 6/1/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work. | 4/26/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean trash from Elevator pit. | 8/15/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | A written maintenance control program shall be kept on site for each elevator. | 8/15/2025 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Emergency lighting shall work. Only one bulb is working. | 5/28/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Wireway between 14 & 15 is missing cover. | 8/15/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light shall be guarded. | 8/15/2025 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | MCP, including PM records and monthly fire service test log, not being properly documented. | 8/15/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 8/15/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Expired State operating certificate in the machine room. |