Inspection
Inspection Details
Equipment ID
14387
14387
Inspection Date
4/8/2020
4/8/2020
Inspection Type
Alteration
Alteration
Inspector Name
Jeffrey Krug
Jeffrey Krug
Mechanic Name
Nicholas Maue
Nicholas Maue
Relief Valve Pressure
Slide
n/a
n/a
Governor Rope Pull
130/600
130/600
Door Closing Force
n/a
n/a
External ID
5c7e8023-bb9c-4739-b0e7-f2d26c8ec4f6
5c7e8023-bb9c-4739-b0e7-f2d26c8ec4f6
Location
Westmoreland Apartments
245 UNION BLVD, SAINT LOUIS, MO
245 UNION BLVD, SAINT LOUIS, MO
Owner
Attn: Larry McFadden
275 on the Park
275 UNION BLVD, St. Louis, MO 63108
Phone: (000) 000-0000
275 on the Park
275 UNION BLVD, St. Louis, MO 63108
Phone: (000) 000-0000
Billing
Attn: Larry McFadden
275 on the Park - Annex
275 UNION BLVD, St. Louis, MO 63108
Phone: (000) 000-0000
275 on the Park - Annex
275 UNION BLVD, St. Louis, MO 63108
Phone: (000) 000-0000
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | x | Car door restrictor shall work. | 10/19/2018 | |
| conversion | conversion | conversion - reinspect | x | In cab emergency telephone shall work. | 10/19/2018 | |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | The fire extinguisher the machine room is expired and shall be replaced by a current testing fire extinguisher. | |||
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | x | Make the door restrictor operational. | 5/14/2019 | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | In cab emergency telephone shall work. | 5/14/2019 | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | In car emergency telephone shall work. | 10/25/2019 | |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | The fire extinguisher in the machine room is expired. A current tested ABC type fire extinguisher shall be kept in the machine room. | |||
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | x | The door restrictor shall be operational. | 2/23/2021 | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 2/23/2021 | |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | The elevator machine room door shall be self-locking and self-closing and shall only be accessible to authorized personnel. | |||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit shall be kept clean. Clean the pit. | |||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit lighting shall be operational. | |||
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Provide a code compliant MCP including onsite documents. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | The car top shall be cleaned. | |||
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 1001.2(a)(12) | Replace the missing handrails in the elevator. | |||
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | |||
| A17.1-1996 : Elevators | 2.6 - Ventilation | 1001.2(b)(6) | The machine room ventilation shall be operational. | |||
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room. | |||
| A17.1-1996 : Elevators | 1.3 - Operating control devices | 1001.2(a)(3) | All lights on the car operating panel shall be operational. | |||
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 1001.2(a)(12) | Electrical devices in the car enclosure shall have covers installed. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | x | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. Note: There is no machine room door at all. | 4/14/2022 | |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site. | |||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. Note: The test tag is expired. | |||
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | The means to restrict opening of the car door shall be operational. | 4/14/2022 | |
| A17.1-1996 : Elevators | 1.15 - sign and operating device symbols | 1001.2(a)(15) | The car identification number shall be painted on, engraved, or securely attached to the car operating panel and shall be a minimum of 1/2" in height. | |||
| A17.1-1996 : Elevators | 1.3 - Operating control devices | 1001.2(a)(3) | The car operating panel car call indicator lights shall all be functional. | |||
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 1001.2(a)(12) | The exposed wiring inside the fixture on the back wall of the elevator cab interior shall be enclosed. | |||
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | The in car emergency lighting shall be operational. | 4/14/2022 | |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The safeties shall be tested as required by A17.2, item 2.29. Note: Winding drum safety access is presently covered by glued on flooring. | 4/14/2022 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | x | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. Note: There is no machine room door at all. | 9/14/2023 | |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | The means to restrict opening of the car door shall be operational. | 9/14/2023 | |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | The in car emergency lighting shall be operational. | 9/14/2023 | |
| A17.1-2016 : Elevators | 4.1 - Car platform guard | 2.15.9 | x | Platform guard shall not be less than 48". Pit depth results in need of a retractable guard or variance approved by State board. If variance is not approved at next board meeting, unit shall be removed from service until proper guard is installed. | 10/25/2023 | |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | x | Elevators that are equipped to operate on emergency power shall be tested with no load in the car, operating on emergency power. All cars to be tested. | 11/26/2024 | |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | x | Emergency power testing could not be completed due to failure of auxiliary generator to operate. Take corrective action and re-test. | 1/13/2025 |