Inspection
Inspection Details
Equipment ID
17392
17392
Inspection Date
4/6/2020
4/6/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
John Hambrough
John Hambrough
Relief Valve Pressure
580
580
Slide
Governor Rope Pull
Door Closing Force
16
16
External ID
9b077a35-8e05-4b62-aa51-693440d249a5
9b077a35-8e05-4b62-aa51-693440d249a5
Location
Trinity Lutheran Church
812 SOULARD ST, SAINT LOUIS, MO
Phone: (314) 231-4092
812 SOULARD ST, SAINT LOUIS, MO
Phone: (314) 231-4092
Owner
Attn: Trinity Lutehran Church- STL
Trinity Lutheran Church- STL
812 Soulard St, St. Louis, MO 63104
Phone: (314) 231-4092
Email: office@trinitystlouis.com
Trinity Lutheran Church- STL
812 Soulard St, St. Louis, MO 63104
Phone: (314) 231-4092
Email: office@trinitystlouis.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.37 Pressure switch | 306.14 Pressure switch | Yes | No | The pressure switch shall be operational according to A17.1 - 306.14 | 4/6/2020 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | The in car emergency lighting shall be operational. | 5/5/2021 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The alarm bell shall be operational on auxiliary power. | 5/5/2021 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | 6/9/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 6/9/2022 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | A record of findings for firefighters' service operation is required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site. | 6/9/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. | 6/9/2022 |
| A17.1-1996 : Elevators | 2.37 - Pressure Switch | 306.14 | Yes | No | The pressure switch does not work. | 5/23/2022 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | Receptacle in the pit shall be ground fault protected. | 6/9/2022 |
| A17.1-1996 : Elevators | 2.14 - Code data plate | 215 | No | No | Install a code date plate. It shall read: "A17.1-1996" | 6/9/2022 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | 6/9/2022 |
| A17.1-1996 : Elevators | 3.10 - Hoistway construction | 1001.2(c)(16) | No | No | Seal all holes in the hoistway and remove all abandoned electrical wiring in hoistway. | 6/9/2022 |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | No | No | All machine room enclosures shall have self-locking door and shall be operable from the interior space without the use of a key. | 6/9/2022 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit ladder shall extend not less than 42" above the sill of the access door. The present ladder does not meet this requirement. | 6/9/2022 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | There is a smoke detector and a heat detector at the top of the hoistway, there is also a heat detector in the machine room. Since there is no shunt trip disconnect in the machine room and there are no sprinklers in the two areas mentioned, verify that these detectors do not affect the operation of the elevator. | 6/9/2022 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspection) | Yes | No | This elevator is equipped with an unsealed overspeed valve. A category 5 test shall be performed and witnessed within 90 days. | 8/8/2023 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Emergency light is not working. | 2/7/2024 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency bell is not working. | 2/7/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 4/1/2025 |