Inspection
Inspection Details
Equipment ID
14904
14904
Inspection Date
4/17/2020
4/17/2020
Inspection Type
Reinspection
Reinspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Relief Valve Pressure
None
None
Slide
Governor Rope Pull
Door Closing Force
None
None
External ID
39860f18-808e-49f5-8745-a5498ca1f68d
39860f18-808e-49f5-8745-a5498ca1f68d
Location
Forshaw
745 S LINDBERGH BLVD, SAINT LOUIS, MO
Phone: (314) 993-5570
745 S LINDBERGH BLVD, SAINT LOUIS, MO
Phone: (314) 993-5570
Owner
Attn: UNK
Forshaw
825 S LINDBERGH BLVD, FRONTENAC, MO 63131
Phone: (000) 000-0000
Forshaw
825 S LINDBERGH BLVD, FRONTENAC, MO 63131
Phone: (000) 000-0000
Billing
Attn: Forshaw
Forshaw
825 S LINDBERGH BLVD, FRONTENAC, MO 63131
Phone: (000) 000-0000
Email: pkennedy@forshaws.com
Forshaw
825 S LINDBERGH BLVD, FRONTENAC, MO 63131
Phone: (000) 000-0000
Email: pkennedy@forshaws.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept dry. Remove the standing water from the pit and correct the source of the leak. | 7/30/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The in car emergency telephone shall be operational. | 4/17/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone still not working | 6/26/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit still has water in it | 7/30/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 4/22/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine room shall have a proper fire extinguisher and shall have current monthly/annual test tag. | 8/22/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 8/22/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Overhead piping (water/drain) shall be guarded or guttered. | 8/22/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room walls and ceiling are water damaged and no longer properly fire rated. Repair/replace all damaged drywall. | 8/22/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit shall be kept clean and dry. Remove rust from pit equipment. Repair/replace rusted equipment as needed and investigate and repair water leak. | 8/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | A current ABC type fire extinguisher shall be provided in the machine room. | 4/14/2025 |