Inspection
Inspection Details
Equipment ID
2800
2800
Inspection Date
6/20/2018
6/20/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Unknown Conversion
Unknown Conversion
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
22
22
External ID
Location
South Bemiston Association
230 S Bemiston, Clayton, MO
Phone: (314) 726-1444
230 S Bemiston, Clayton, MO
Phone: (314) 726-1444
Owner
The Michelson Organization
7701 Forsyth, Suite 900, Clayton, MO 63105
7701 Forsyth, Suite 900, Clayton, MO 63105
Billing
Attn: The Michelson Organization
7701 Forsyth, Suite 900, , MO 63105
7701 Forsyth, Suite 900, , MO 63105
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)8 | Yes | Yes | Upon performing the required five year full load, the elevator safety governor was found to be worn to a degree that the mechanical and electrical protection devices would not activate within the required limits. Repair or replacement of the governor is required and a reinspection shall be performed before the elevator can be returned to service. | 6/29/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The testing has not been completed on the elevator at this time. The weight test shall be performed, safeties set, and buffers compressed before the inspection is completed. | 6/29/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The the category 5 testing has not been completed on the elevator at this time. The weight test shall be performed, safeties set, and buffers compressed before the inspection is completed. | 6/29/2020 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Repair the ends of the counterweight side of two ropes. Ropes need to be seized or banded to prevent unraveling. | 7/8/2021 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Elevator has a hoist rope that is slipping across the sheave, the rope is worn. The driver sheave is worn from the rope slippage, repair or replacement of rope and sheave is recommended. Re-inspection required | 9/28/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Car top door operator cambox has broken flex, repair or replace flex | 12/9/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Unit has variance regarding machine room door equipment that has not been met. Post sign on machine room door stating " CAUTION Keep safe distance from elevator equipment" and provide yellow caution tape / paint around all elevator equipment in machine room | 12/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Need to replace broken "wooden" guide on counterweight buffer | 12/9/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)1 | No | No | Car top door operator cambox has broken flex / repair or replace flex | 12/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Car top door operator cam box has broken flex, needs repaired |