Inspection
Inspection Details
Equipment ID
13611
13611
Inspection Date
7/18/2017
7/18/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Rick Buttice
Rick Buttice
Mechanic Name
Relief Valve Pressure
Slide
2
2
Governor Rope Pull
40/100
40/100
Door Closing Force
27
27
External ID
Location
5393 Nagel Apartments
5939 Nagel Ave, St. Louis, MO
Phone: (314) 752-4863
5939 Nagel Ave, St. Louis, MO
Phone: (314) 752-4863
Owner
Allegro
PO Box 322-6614 Clayton Rd, Richmound Heights, MO 63117
PO Box 322-6614 Clayton Rd, Richmound Heights, MO 63117
Billing
Attn: Allegro
1140 Lay Rd, , MO 63124
1140 Lay Rd, , MO 63124
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Water in pit. | 11/2/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Provide a written maintenance control program. 8.6.1.2.1 | 11/2/2018 |
| MO Minimum : Elevators | (I) - Pits | (I)2 | No | No | Counterweight buffer stand is rusted out and not secured. Replace deteriorated buffer stand within 15 days or unit will be removed from service. | 10/19/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace seized up counterweight rollers. | 10/19/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide written maintenance control program. | 10/19/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Maintenance control program is required. | 10/19/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Test car safeties with rated load at rated speed. Re-inspection required | 6/28/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Test car safeties with rated load at rated speed. Re-inspection required | 10/7/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Full load test has not been completed. Need to test car safeties with rated load at rated speed within 30 days or elevator will be red-tagged and removed from service. Re-inspection required | 10/23/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current state operating certificate shall be displayed in elevator machine room. | 7/2/2026 |