Inspection
Inspection Details
Equipment ID
16500
16500
Inspection Date
5/1/2020
5/1/2020
Inspection Type
Reinspection
Reinspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Benjamin Williams
Benjamin Williams
Relief Valve Pressure
Slide
None
None
Governor Rope Pull
None
None
Door Closing Force
None
None
External ID
eaf8a131-c1f2-4a70-a33b-0a4fa65ef158
eaf8a131-c1f2-4a70-a33b-0a4fa65ef158
Location
Hampden Hall Apts
4404 MCPHERSON AVE, SAINT LOUIS, MO
Phone: (314) 652-4400
4404 MCPHERSON AVE, SAINT LOUIS, MO
Phone: (314) 652-4400
Owner
Attn: Asprient Properties
Asprient Properties
PO BOX 28514, SAINT LOUIS, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Asprient Properties
PO BOX 28514, SAINT LOUIS, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | conversion - reinspect | x | Existing cab emergency telephone does not work and shall be repaired and tested. | 2/20/2019 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The in car emergency telephone shall be operational. | 5/1/2020 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | A light guard shall be installed on the car top lighting. | 9/30/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | The pit light shall be operational and have a guard installed. | 9/30/2019 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | The fire service phase 1 & phase 2 key switches shall be legible. | 9/30/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | The pit shall be kept clean. Remove the debris from the pit. | 9/30/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light shall work and have guard to protect bulb | 12/30/2021 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | Adjust car door restrictor to work | 1/21/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide fire extinguisher in machine room | 12/30/2021 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide a fire extinguisher in the machine room | 12/30/2021 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Repair inoperative emergency phone | 1/19/2023 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Provide machine room ventilation fan to work.(‘96. 101.5b) | 10/1/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide current year tested fire extinguisher in the elevator machine room. | 10/1/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency lights are not working, bell is ok. | 9/6/2023 |