Inspection
Inspection Details
Equipment ID
2877
2877
Inspection Date
5/24/2018
5/24/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
NA
NA
External ID
2877
2877
Location
Jefferson Barracks Pump
100 S. Gark, St. Louis, MO
Phone: (314) 638-5047
100 S. Gark, St. Louis, MO
Phone: (314) 638-5047
Owner
Metropolitan Sewer District STL
2350 Market St, St. Louis, MO 63103-2555
2350 Market St, St. Louis, MO 63103-2555
Billing
Attn: Metropolitan Sewer District
Accounts Payable
2350 Market St, , MO 63103-2555
Accounts Payable
2350 Market St, , MO 63103-2555
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Make repairs in order for annual test to be conducted. Unit shut down by MSD | 9/27/2018 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | No | No | Repair phone in car | 10/17/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Certificate in machine room | 10/17/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | Yes | Phone inoperative. Red tagged due to location of elevator and possible entrapment issue. Spoke to Gus to clarify. | 11/25/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | The original access door on the controller was removed or misplaced and replaced with a combustible door .Controller Access panel must be made of a non combustible material | 8/6/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)6 | No | Yes | The current hoistway door interlock does not prevent the door from being opened when the car is away from the landing. The door shall be provided with approved interlocks. Red tag, unit placed out of service until repaired and reinspected. | 8/6/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | The Current operating certificate shall be posted in the machine room in a non combustible frame | 8/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | There shall be maintenance records in the elevator machine room or accessible to the inspector. Shall consist of maintenance task such as callbacks, examinations, test, adjustments, and replacements. | 8/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Car safety pan device has been removed or misplaced and replaced with a combustible material. The safety pan must be replaced with a non combustible material. | 8/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | The gate restrictor device shall be repaired so the door or gate of the car will be properly restricted and restrict the opening of the gate with the maximum of 4 inches when the car is away from a landing zone. Reinspection is required. | 9/15/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)11 | No | Yes | The hoisting chain deteriorated when performing the required 5 year test and shall be replaced a repair and reinspection is required before the elevator can be returned to service. | 8/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Gate restrictor must be repaired. | |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)9 | Yes | Yes | Doors shall be equipped with interlocks. Unit red tagged until repaired. |