Inspection
Inspection Details
Equipment ID
11551
11551
Inspection Date
6/11/2018
6/11/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dennis Parker
Dennis Parker
Mechanic Name
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
28
28
External ID
Location
Pioneer I
7700 Clayton Rd, Richmond Heights, MO
Phone: (636) 646-0020
7700 Clayton Rd, Richmond Heights, MO
Phone: (636) 646-0020
Owner
7700 Clayton LLC
7700 Clayton Rd #101, St. Louis, MO 63117
7700 Clayton Rd #101, St. Louis, MO 63117
Billing
Attn: Intelica
600 Emerson Suite 210, , MO 63141
600 Emerson Suite 210, , MO 63141
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Replace emergency light and alarm batteries | 2/5/2021 |
| conversion | conversion | n/a | No | No | Make Ceiling removable at escape hatch (no way to egress) | 2/5/2021 |
| conversion | conversion | n/a | No | No | Bolt Escape hatch closed | 2/5/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.4 - Hoistway door locking devices | 8.11.2.1.4(d) | Yes | No | The top floor interlock is missing a cover plate exposing the electrical contacts to accidental contact. A cover plate shall be reinstalled. | 1/31/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean the pit. | 2/5/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate. | 2/5/2021 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(a)(1) | No | No | Provide MCP | 7/19/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.4 Plunger Gripper Testing | No | No | Provide testing of plunger gripper. | 7/19/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A copy of the MCP shall be kept in the machine room for each unit | 7/19/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be posted in the machine room. | 7/19/2023 |