Inspection
Inspection Details
Equipment ID
17650
17650
Inspection Date
6/2/2020
6/2/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Brent Davis
Brent Davis
Relief Valve Pressure
NA
NA
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
24c7090b-b698-4162-b63b-f7728a95b692
24c7090b-b698-4162-b63b-f7728a95b692
Location
Lucas Lofts
1114 LUCAS AVE, SAINT LOUIS, MO
Phone: (314) 721-8427
1114 LUCAS AVE, SAINT LOUIS, MO
Phone: (314) 721-8427
Owner
Attn: Lucas Lofts Condo Assoc. C/O Rafco Properties
Lucas Lofts Condo Assoc. C/O Rafco Properties
1117-1123 Washington Ave., St. Louis, MO 63101
Phone: (000) 000-0000
Lucas Lofts Condo Assoc. C/O Rafco Properties
1117-1123 Washington Ave., St. Louis, MO 63101
Phone: (000) 000-0000
Billing
Attn: Lucas Lofts
Lucas Lofts
7700 FORSYTH BLVD STE 100, CLAYTON, MO 63105
Phone: (314) 721-8427
Email: Matt@rafcoprop.com
Lucas Lofts
7700 FORSYTH BLVD STE 100, CLAYTON, MO 63105
Phone: (314) 721-8427
Email: Matt@rafcoprop.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Emergency phone not working | 5/31/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Repair phone in car | 6/2/2020 |
| conversion | conversion | n/a | No | No | Post current state certificate in machine room | 2/6/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 8/10/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide a proper maintenance control program in machine room | 8/10/2020 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Provide monthy fire service test & document on log in machine room | 8/10/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Clean oil from pit floor | 8/10/2020 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test and document on log in machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Repair light in car | 4/1/2022 |
| A17.1-1996 : Elevators | 2.17 - Drive machine brake | 210.8 | Yes | No | Repair emergency brake release | 4/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Replace baisel on phase 1 fire service switch | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Repair fan in car | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide a maintenance control program and post in the machine room | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Reinspection for emergency brake release tested failed reinspection needed | 6/28/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Replace missing car ceiling tile. |