Inspection
Inspection Details
Equipment ID
2878
2878
Inspection Date
4/28/2020
4/28/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Michael Bailey
Michael Bailey
Mechanic Name
Bryan Hesskamp
Bryan Hesskamp
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
External ID
31967a67-625e-4304-8637-204714df00e0
31967a67-625e-4304-8637-204714df00e0
Location
Fillmore Pump Station
100 FILLMORE ST, SAINT LOUIS, MO
Phone: (314) 638-5047
100 FILLMORE ST, SAINT LOUIS, MO
Phone: (314) 638-5047
Owner
Attn: Chilufya Kaoma
Metropolitan St. Louis Sewer District
1025 Grand Glaize Parkway, Valley Park, MO 63088
Phone: (636) 861-6763
Email: ckaoma@stlmsd.com
Metropolitan St. Louis Sewer District
1025 Grand Glaize Parkway, Valley Park, MO 63088
Phone: (636) 861-6763
Email: ckaoma@stlmsd.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Repair alarm bell in car | 5/19/2020 |
| conversion | conversion | n/a | No | No | Provide access to hoistway at top level | 5/19/2020 |
| conversion | conversion | n/a | No | No | Repair phone in car | 5/19/2020 |
| conversion | conversion | n/a | No | No | Post current state certificate by machine space | 5/19/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency phone. | 4/28/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | The original access door on the controller was removed or misplaced and replaced with a combustible door .Controller Access panel must be made of a non combustible material | 8/6/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)6 | No | Yes | The current hoistway door interlock does not prevent the door from being opened when the car is away from the landing. The door shall be provided with approved interlocks. | 8/6/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | The Current operating certificate shall be posted in the machine room in a non combustible frame | 8/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | Yes | The gate restrictor device shall be repaired so the door or gate of the car will be properly restricted and restrict the opening of the gate with the maximum of 4 inches when the car is away from a landing zone. | 9/15/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | There shall be maintenance records in the elevator machine room or accessible to the inspector. Shall consist of maintenance task such as callbacks, examinations, test, adjustments, and replacements | 8/6/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)9 | Yes | Yes | Door shall be equipped with interlocks. Unit red tagged until repaired. |