Inspection
Inspection Details
Equipment ID
742
742
Inspection Date
6/8/2020
6/8/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
26f5da7c-b5ef-47ec-82ae-983f8d73db41
26f5da7c-b5ef-47ec-82ae-983f8d73db41
Location
Saxony Condos
8631 OLD BONHOMME RD, SAINT LOUIS, MO
Phone: (314) 845-0377
8631 OLD BONHOMME RD, SAINT LOUIS, MO
Phone: (314) 845-0377
Owner
Attn: Efthim Realtors Co
Efthim Realtors Co
4177 CRESCENT DR STE A, SAINT LOUIS, MO 63129
Phone: (000) 000-0000
Email: efthimmgmt@sbcglobal.net
Efthim Realtors Co
4177 CRESCENT DR STE A, SAINT LOUIS, MO 63129
Phone: (000) 000-0000
Email: efthimmgmt@sbcglobal.net
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | Need maintenance control program on site posted on controller | 10/16/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | Emergency phone not working line is dead at controller | 10/23/2020 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | Need testing procedures in the MCP | 12/15/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency phone not working | 10/5/2021 | |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | Perform monthly fire service and document on log in machine room | 7/22/2024 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Repair emergency phone | 5/18/2023 | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Clean pit | 7/22/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency light in car not working | 5/18/2023 | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Clean pit | 7/22/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Repair phone in car | 6/11/2024 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current state certificate in machine room | 7/26/2024 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Need to add lighting in machine room code requires 19 foot candles at the floor level | 7/26/2024 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7.1.2 Minimum Illumination | REPLACE BURN OUT LIGHT IN THE CAR | 5/28/2025 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Rooms and Machinery Spaces | REMOVE ALL NON ELEVATOR STORAGE FROM THE MACHINE ROOM | 5/28/2025 |