Inspection
Inspection Details
Equipment ID
6839
6839
Inspection Date
6/2/2020
6/2/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
510
510
Slide
Governor Rope Pull
Door Closing Force
16
16
External ID
737ee8cc-d9a9-465b-bd30-78bb94c00638
737ee8cc-d9a9-465b-bd30-78bb94c00638
Location
LaQuinta-Hazelwood
318 TAYLOR RD, HAZELWOOD, MO
Phone: (314) 731-4200
318 TAYLOR RD, HAZELWOOD, MO
Phone: (314) 731-4200
Owner
LaQuinta-Inn
318 TAYLOR RD, HAZELWOOD, MO 63042-2027
318 TAYLOR RD, HAZELWOOD, MO 63042-2027
Billing
Attn: La Quinata Inn
318 TAYLOR RD, HAZELWOOD, MO 63042-2027
318 TAYLOR RD, HAZELWOOD, MO 63042-2027
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove storage and trash from machine room. | 10/12/2018 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit and car top. | 10/12/2018 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove trash from machine room. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Replace worn car door guide shoe, and clean corresponding tract. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate inside elevator equipment room. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate. | 9/26/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine room needs to be cleaned | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Cab emergency lights do not work, needs repaired. Re-inspection required | 7/8/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current certificate shall be displayed in the elevator machine room | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace broken 3rd floor car call button. |