Inspection
Inspection Details
Equipment ID
8948
8948
Inspection Date
6/21/2018
6/21/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
21
21
External ID
Location
Wells Fargo - Bldg D
1 N Jefferson, St. Louis, MO
Phone: (314) 955-7007
1 N Jefferson, St. Louis, MO
Phone: (314) 955-7007
Owner
Wells Fargo
1 North Jefferson Ave Rm H0001-L11, St. Louis, MO 63105
1 North Jefferson Ave Rm H0001-L11, St. Louis, MO 63105
Billing
Attn: Wells Fargo
1 North Jefferson Ave Rm H0001-L11, , MO 63105
1 North Jefferson Ave Rm H0001-L11, , MO 63105
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 2.14 - Code data plate | 8.9 | Yes | No | Install alteration code data plate. Re-inspection required | 4/13/2024 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.1.6(h) Audible/Visual Signal (Re-Inspection) | Yes | No | Fireman's hat does not flash when machine room smoke detectors are tripped. Retest smoke detectors. Re-inspection required | 4/13/2024 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | Yes | No | Car light disconnect in machine room shall be fused, externally operated and lockable in the off position. Re-inspection required | 4/13/2024 |
| A17.1-2016 : Elevators | 3.20 - Governor rope | 2.18.5 | Yes | No | Install governor rope data tag. Re-inspection required | 4/13/2024 |
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | Yes | No | Replace missing electric duct cover in hoistway. Re-inspection required | 4/13/2024 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8 | Yes | No | Install wiring in electric duct in machine room. Re-inspection required | 4/13/2024 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Test elevator on emergency power with full load. Re-inspection required | 4/13/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Need to perform the following tests to complete inspection: Emergency generator power operation & fire service. Re-inspection required | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm in car did not work. Re-inspection required | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light in car did not work. Re-inspection required |