Inspection
Inspection Details
Equipment ID
7643
7643
Inspection Date
6/5/2020
6/5/2020
Inspection Type
Reinspection
Reinspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
2bc7e0ab-aa06-4971-ae14-c794d1bde6a9
2bc7e0ab-aa06-4971-ae14-c794d1bde6a9
Location
Masonic Temple Association of St. Louis
3681 LINDELL BLVD, SAINT LOUIS, MO
Phone: (314) 533-5460
3681 LINDELL BLVD, SAINT LOUIS, MO
Phone: (314) 533-5460
Owner
Attn: UNK
3681 LINDELL BLVD
3681 LINDELL BLVD, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
3681 LINDELL BLVD
3681 LINDELL BLVD, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
Billing
Attn: UNK
3681 LINDELL BLVD
3681 LINDELL BLVD, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
3681 LINDELL BLVD
3681 LINDELL BLVD, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | Yes | The cab lighting shall be operational and not less then 5fc. Elevator Red Tagged due to alarm bell and cab lighting both not working. There is no phone or intercom. | 6/5/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | Yes | The alarm bell shall be operational. Elevator Red Tagged due to alarm bell and cab lighting both not working. There is no phone or intercom. | 6/5/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room shall have permanent lighting of not less than 10 fc. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room shall be enclosed and accessible only to authorized personnel. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | The lighting in the stairway going up to the machine room shall be operational. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide a current tested ABC fire extinguisher in the machine room. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Car gate and hoistway doors, as well as governor pullout/pullthru, and governor switch and jaw were the only tests witnessed on 2/21/2020. All other tests required by MO CSR 40-5.090 have yet to be performed and shall be rescheduled. Other deficiencies may be noted after testing is complete. | 6/5/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room shall have permanent lighting of not less than 10 fc. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room shall be enclosed and accessible only to authorized personnel. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | The lighting in the stairway going up to the machine room shall be operational. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide a current tested ABC fire extinguisher in the machine room. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Car gate and hoistway doors, as well as governor pullout/pullthru, and governor switch and jaw were the only tests witnessed on 2/21/2020. All other tests required by MO CSR 40-5.090 have yet to be performed and shall be rescheduled to complete category 5 test and periodic inspection. Other deficiencies may be noted after testing is complete. | 1/25/2021 |