Inspection
Inspection Details
Equipment ID
9075
9075
Inspection Date
6/15/2020
6/15/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Daniel Novak
Daniel Novak
Relief Valve Pressure
250
250
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
bde8c188-34ce-4529-beaa-2934a4fa7037
bde8c188-34ce-4529-beaa-2934a4fa7037
Location
Brittain-Richerson Building
224 N 4TH ST, SAINT JOSEPH, MO
Phone: (816) 465-0049
224 N 4TH ST, SAINT JOSEPH, MO
Phone: (816) 465-0049
Owner
Full Circle Holdings LLC
224 N 4TH ST, SAINT JOSEPH, MO 64501-1756
224 N 4TH ST, SAINT JOSEPH, MO 64501-1756
Billing
Attn: Full Circle Holdings
2400 FREDERICK AVE STE 101, SAINT JOSEPH, MO 64506-2761
2400 FREDERICK AVE STE 101, SAINT JOSEPH, MO 64506-2761
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Install duct cover on wire raceway in machine room. | 7/1/2020 |
| A17.1-2016 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 | No | No | Scavenger pump in pit pumps oil to hydraulic tank in machine room. Need to remove scavenger pump. | 7/1/2020 |
| A17.1-1996 : Elevators | 2.14 - Code data plate | 215 | No | No | Need to post code data plate on controller or mainline disconnect. Elevator installed 2001. | 7/1/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Remove rag box, and debris from cartop. | 7/1/2020 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Emergency light does not operate | 3/3/2021 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency bell does not operate | 3/3/2021 |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | No | No | Machine room access door shall be self-locking and non-defeatable | 12/8/2022 |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 102 | No | No | Install cover over car door operator electrical control board. | 12/8/2022 |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 102 | No | No | Install cover on electrical wire trough located on top of the elevator | 12/8/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not operate | 12/14/2023 |
| A17.1-1996 : Elevators | 3.9 - Floor and emergency identification numbering | 100.7 | No | No | Label inside of hoistway doors with a numeral | 11/6/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current state operating certificate not displayed in machine room | 11/6/2023 |
| A17.1-2016 : Elevators | 1.15 - sign and operating device symbols | 8.6.1.6.7 | No | No | Post In Case of Fire signage next to hall button fixture at each landing | 11/6/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | REMOVE OIL AND DEBRIS FROM PIT |