Inspection
Inspection Details
Equipment ID
144
144
Inspection Date
6/22/2020
6/22/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
John Osowski
John Osowski
Relief Valve Pressure
400
400
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
e0421302-9fe1-47e1-972c-5bd1046cf196
e0421302-9fe1-47e1-972c-5bd1046cf196
Location
Fitters 5th Street Pub
500 S OHIO AVE, SEDALIA, MO
Phone: (660) 827-6500
500 S OHIO AVE, SEDALIA, MO
Phone: (660) 827-6500
Owner
Attn: Fitters 5th Street Pub
Fitters 5th Street Pub
500 S OHIO AVE, SEDALIA, MO 65301
Phone: (660) 827-6500
Email: fitters5thstpub@gmail.com
Fitters 5th Street Pub
500 S OHIO AVE, SEDALIA, MO 65301
Phone: (660) 827-6500
Email: fitters5thstpub@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door must be self-locking | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room light not working | |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Pit sump hole needs non combustible flat cover. Cover now is more like cheap barbecue grill with bigger holes. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door must be self-locking | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room light switch not working. ? No light. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door must be self-locking | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Hoistway doors missing pick-up rollers. Replace | |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Sump pump hole needs correct cover | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | In case of fire don't use elevator signage needed | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door must be self-closing and self-locking. Existing door and frame broken | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Oil sludge needs cleaned from pit | |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Pit sump hole needs correct cover |