Inspection
Inspection Details
Equipment ID
14546
14546
Inspection Date
6/17/2020
6/17/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Bryan Hesskamp
Bryan Hesskamp
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
1fc30ee0-4fd6-42f1-80d8-d13a7dfe5bdd
1fc30ee0-4fd6-42f1-80d8-d13a7dfe5bdd
Location
National Rent to Own
3458 UNION BLVD, SAINT LOUIS, MO
Phone: (314) 381-7777
3458 UNION BLVD, SAINT LOUIS, MO
Phone: (314) 381-7777
Owner
Attn: National Rent to Own
National Rent to Own
10929 Page Ave, St. Louis, MO 63132
Phone: (000) 000-0000
National Rent to Own
10929 Page Ave, St. Louis, MO 63132
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)2 | Elevators shall have warning chains hung within 2" of the edge of the platform on the entrance sides. Chains shall be of number ten (10) US gauge wire or of equal size. Chains shall extend not less than 5' below the platform and shall not be spaced more than 4" apart. | 11/6/2020 | ||
| MO Minimum : Elevators | (I) - Pits | (I)2 | Replace pit channel. | 11/6/2020 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Provide code compliant car lighting (2.5 ft candles) | 11/6/2020 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Car top light needs to be wired per NEC. | 11/6/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Provide guard on lights in machine room. | 11/6/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide updated fire extinguisher in machine room. | 11/6/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Seal missing on governor. | 11/6/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | Provide maintenance on brake system. Clean and lub pins. | 11/6/2020 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | Provide anti-rotation hoist ropes. | 11/6/2020 | ||
| MO Minimum : Elevators | (I) - Pits | (I)5 | Provide pit ladder. | 11/6/2020 | ||
| MO Minimum : Elevators | (I) - Pits | (I)2 | Provide counterweight buffer. | 11/6/2020 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)1 | Cab is missing section of car top enclosure, replace as needed. | 11/6/2020 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate. | 11/6/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Provide guards on lights in machine room. | |||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | Lights in car shall be code compliant, 2.5 ft candles, minimum. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide updated fire extinguisher in machine room. |