Inspection
Inspection Details
Equipment ID
17626
17626
Inspection Date
7/1/2020
7/1/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Jeffrey Miller
Jeffrey Miller
Relief Valve Pressure
480
480
Slide
Governor Rope Pull
Door Closing Force
15
15
External ID
ff5f5983-76ba-4b4a-997e-d2d8168913c0
ff5f5983-76ba-4b4a-997e-d2d8168913c0
Location
Field School Lofts
4466 OLIVE ST, SAINT LOUIS, MO
Phone: (314) 680-4544
4466 OLIVE ST, SAINT LOUIS, MO
Phone: (314) 680-4544
Owner
Field Landlord L.P.
4500 OLIVE ST APT K, SAINT LOUIS, MO 63108-1841
4500 OLIVE ST APT K, SAINT LOUIS, MO 63108-1841
Billing
Attn: Field Landlord L.P.
4500 OLIVE ST APT K, SAINT LOUIS, MO 63108-1841
4500 OLIVE ST APT K, SAINT LOUIS, MO 63108-1841
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | Yes | No | Make door restrictor operational. | 10/18/2018 |
| A17.1-1996 : Elevators | 3.3 - Top-of-car operating device | 1001.2(c)(3) | No | No | Make car top run station operational. - Reinspection Required | 10/25/2018 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Red Tag) | Yes | No | In cab emergency telephone shall work. | 10/18/2018 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Existing cab emergency telephone shall work with 24/7 support. | 10/24/2018 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 10/25/2018 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light inoperative. | 11/24/2020 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Service fire extinguisher. | 11/1/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light does not work. | 6/16/2021 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Fire extinguisher is expired | 11/1/2022 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the state operating certificate shall be displayed in the elevator machine room | 11/1/2022 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 | No | No | Pit light bulbs shall be guarded | 11/1/2022 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | No | No | Smoke device in pit needs to be remounted on electrical box | 11/1/2022 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.7 Firefighter' Service Operating Procedures | Yes | No | Elevator shall be removed from phase I emergecny recall by keying phase I switch to RESET then OFF. Unit had to be reset from controller to return to automatic operation. | 4/16/2026 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | Pit shall be kept clean. Remove excess debris, excessive dust, and oil. | 4/16/2026 |
| A17.1-1996 : Elevators | 2.4 - Machine space | 100.3d | No | No | Machine lighting shall be repaired, 1 or more bulbs not working. | 4/16/2026 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.7 Firefighter' Service Operating Procedures | No | No | Fire service testing must be documented montly. | 4/16/2026 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and realted on-site documentation shal be provided in the machine room. No MCP documentation predent for 2022, 2023, and 2024. | 4/16/2026 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.7 Firefighter' Service Operating Procedures | Yes | No | Elevator shall be removed from phase I emergecny recall by keying phase I switch to RESET then OFF. Unit had to be reset from controller to return to automatic operation. | |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | Pit shall be kept clean. Remove excess debris, excessive dust, and oil. | |
| A17.1-1996 : Elevators | 2.4 - Machine space | 100.3d | No | No | Machine lighting shall be repaired, 1 or more bulbs not working. | |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.7 Firefighter' Service Operating Procedures | No | No | Fire service testing must be documented montly. | |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and realted on-site documentation shal be provided in the machine room. No MCP documentation predent for 2022, 2023, and 2024. |