Inspection
Inspection Details
Equipment ID
2148
2148
Inspection Date
6/11/2020
6/11/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
David Scott
David Scott
Relief Valve Pressure
400
400
Slide
Governor Rope Pull
Door Closing Force
18
18
External ID
9393e3a1-cf9c-40e4-a46d-c8e9ce6d0fdf
9393e3a1-cf9c-40e4-a46d-c8e9ce6d0fdf
Location
OWL Seniors, LP
5800 ARSENAL ST, SAINT LOUIS, MO
Phone: (314) 645-3567
5800 ARSENAL ST, SAINT LOUIS, MO
Phone: (314) 645-3567
Owner
OWL Seniors, LP
5800 ARSENAL ST, SAINT LOUIS, MO 63139-1656
5800 ARSENAL ST, SAINT LOUIS, MO 63139-1656
Billing
Attn: OWL Seniors, LP
5800 ARSENAL ST, SAINT LOUIS, MO 63139-1656
5800 ARSENAL ST, SAINT LOUIS, MO 63139-1656
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Clean Drip Pan (remove oil) in machine room | 8/31/2018 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. | 7/8/2021 |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | Yes | No | The means to restrict opening of the car door shall be operational. | 8/11/2021 |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | No | No | Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. | 7/8/2021 |
| A17.1-1996 : Elevators | 1.16 - Rated load, platform area, and data plate | 1001.2(a)(16) | No | No | A capacity plate shall be provided in the car. | 7/8/2021 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Up-to-date operating certificate required in the machine room. | 10/29/2024 |
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.1 | No | No | Water pipe above the hydraulic tank shall be guarded or guttered to divert any potential leaks away from tank. | 10/29/2024 |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | No | No | Machine room shall not be used for storage. There is also a sink in the machine room. Remove the sink or separate equipment per code. Customer may need to apply for a variance. | 10/29/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 11/19/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 8/1/2025 |