Inspection
Inspection Details
Equipment ID
16303
16303
Inspection Date
7/15/2020
7/15/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
450
450
Slide
Governor Rope Pull
Door Closing Force
23F 22R
23F 22R
External ID
2d0cf836-7d13-46a9-8de3-6f94a78f22cd
2d0cf836-7d13-46a9-8de3-6f94a78f22cd
Location
Webster Groves High School
100 SELMA AVE, WEBSTER GROVES, MO
Phone: (314) 963-6400
100 SELMA AVE, WEBSTER GROVES, MO
Phone: (314) 963-6400
Owner
Webster Groves School District
3232 S BRENTWOOD BLVD, WEBSTER GROVES, MO 63119-1781
3232 S BRENTWOOD BLVD, WEBSTER GROVES, MO 63119-1781
Billing
Attn: Webster Groves School District
3232 S BRENTWOOD BLVD, WEBSTER GROVES, MO 63119-1781
3232 S BRENTWOOD BLVD, WEBSTER GROVES, MO 63119-1781
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 204.7 | No | No | Replace car top light and guard. | 1/6/2021 |
| A17.1-1996 : Elevators | 6.3 - Firefighters' service (A17.1-1984 through A17.1a-1988 and A17.3) | 112.3d | Yes | Yes | Phase II fire service to work per the code. Did NOT red tag elevator. | 9/10/2019 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light does not work. | 12/8/2020 |
| A17.1-1996 : Elevators | 2.35 - Supply Line and Shutoff Valve | 303 | No | No | Remove temporary wood pit supply line supports and firmly anchor line to floor with noncombustable supports. | 1/6/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | The hoistway doors at a number of landings are not self-closing. The hoistway doors shall be adjusted. | 5/18/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | The hoistway door at the top landing is missing a door retaining gib.. The door retaining gib shall be reinstalled. | 5/18/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | The front door operator cover has been removed, reinstall cover to prevent accidental contact by maintenance and emergency personnel. | 5/18/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | The hoistway door interlock cover is missing, reinstall cover to prevent accidental contact by maintenance and emergency personnel. | 5/18/2026 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | Yes | No | 211.3(b)(5) The “bypass” operation is not operational and is only resetting the elevator phase I operation. Reinitiate “bypass” operation to operate to the correct version of fire service this elevator is installed to. | 6/13/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | There shall be maintenance records kept in the elevator machine room accessible to the inspector depicting dates and descriptions of maintenance tasks performed, callbacks, examinations, tests, adjustments, replacements and wiring diagrams. This shall be in accordance to the requirements in the Maintenance Control Program. Electronic means has NOT been approved by the State of Missouri. | 5/18/2026 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | Yes | No | 211.3(b)(5) The “bypass” operation is not operational and is only resetting the elevator phase I operation. Reinitiate “bypass” operation to operate to the correct version of fire service this elevator is installed to. This shall be corrected and reinspected within 30 days or the elevator shall be removed from service until repaired. | 5/7/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | State operating certificate shall be displayed in elevator Machine room. | 5/18/2026 |