Inspection
Inspection Details
Equipment ID
22448
22448
Inspection Date
7/29/2020
7/29/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
Slide
Instantaneous
Instantaneous
Governor Rope Pull
20/100
20/100
Door Closing Force
F-23 R-23
F-23 R-23
External ID
f5dacbd6-7b33-4f40-b808-a4d444019afe
f5dacbd6-7b33-4f40-b808-a4d444019afe
Location
The Standard
3853 FOREST PARK AVE, SAINT LOUIS, MO
Phone: (314) 565-4411
3853 FOREST PARK AVE, SAINT LOUIS, MO
Phone: (314) 565-4411
Owner
Attn: The Standard
The Standard
3853 Forest Park Ave, St. Louis, MO 63108
Phone: (314) 534-9248
Email: kbishop@thestandardstlouis.com
The Standard
3853 Forest Park Ave, St. Louis, MO 63108
Phone: (314) 534-9248
Email: kbishop@thestandardstlouis.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Need copy of current state operating certificate in machine room. | 5/10/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | The pit shall be kept dry. | 5/10/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 5/10/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 7/2/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Backup battery rescue is not working. | 10/6/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.6 - Ventilation | 2.7.5.2 | No | No | Provide proper machine room ventilation. | 9/15/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.6 - Ventilation | 2.7.5.2 | No | No | Control space shall be climate controlled. Machine rooms shall be provided with natural or mechanical means to keep the ambient air temperature and humidity in the range, specified by the elevator equipment manufacturer to ensure safe and normal operation of the elevator. The temperature and humidity range shall be permanently posted in the machine room. | 9/15/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 9/15/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current state operating certificate shall be displayed in the machine roon in a non-combustible frame with a clear cover. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | No | No | Provide signage indicating the source of feed for mainline and 110 volt discconects in control space. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.16.8 | Yes | No | Automatic return unit is not functioning posing possible entrapment in the event of building power loss. |