Inspection
Inspection Details
Equipment ID
953
953
Inspection Date
8/6/2020
8/6/2020
Inspection Type
Reinspection
Reinspection
Inspector Name
Timothy Trout
Timothy Trout
Mechanic Name
Stephen Long
Stephen Long
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
26
26
External ID
295cefeb-f66d-4d6b-adf8-d2fff566b392
295cefeb-f66d-4d6b-adf8-d2fff566b392
Location
Southwest Power Station
FARM ROAD 115 & 164, SPRINGFIELD, MO
Phone: (417) 761-4932
FARM ROAD 115 & 164, SPRINGFIELD, MO
Phone: (417) 761-4932
Owner
Attn: Cody Marshall
City Utilities of Springfield
301 E CENTRAL ST, SPRINGFIELD, MO 65802
Phone: (417) 831-8492
Email: cody.marshall@cityutilities.net
City Utilities of Springfield
301 E CENTRAL ST, SPRINGFIELD, MO 65802
Phone: (417) 831-8492
Email: cody.marshall@cityutilities.net
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Car door exceeds 30 pounds of torque- Reduce to under 30 pounds | 6/4/2019 |
| conversion | conversion | n/a | No | No | Replace pit light | 6/4/2019 |
| conversion | conversion | n/a | No | No | Emergency light and bell doesn't work . | 6/4/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair the emergency phone as there is no dial tone. | 8/6/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Replace the light tubes in the car ceiling. | 8/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Replace the missing braile plates floor 1 and 2 | 8/6/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Replace the burnt out light tubes in the machine room. | 8/6/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room | 8/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | Replace the worn door gibbs the door is draging | 10/27/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Replace the missing light tubes in the car ceiling. | 2/3/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 8.11.2.1.3(z) | No | No | Replace the badly roughed govenor rope | 7/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 8.11.2.1.3(z) | No | No | Replace the very badly rouged governor rope due to excessive rouging. | 7/14/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Replace the compensation rope due to excessive damage to the covering in many places. | 2/3/2026 |
| MO Minimum : Elevators | (N) - Guide Rails | (N)2 | No | No | Repair or replace the lower sections of both guide rails due to excessive rusting from standing water in the pit. | 2/3/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)2 | No | No | Repair or replace both of the buffers due to excessive rust damage due to standing water in the pit. | 2/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Replace the govoner rope due to excessive rouging and broken wire lays near the bottom . | 5/31/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)3 | No | No | Repair the damaged comp chain jacket, as it has been snagged and damaged. | 2/3/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Replace the burnt out pit light. | 2/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | replace the burnt out light tubes in the machine room ceiling , you are to provide a minimum of 20 ftc at the machine room floor. | 2/3/2026 |