Inspection
Inspection Details
Equipment ID
2995
2995
Inspection Date
7/10/2020
7/10/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Bryan Hesskamp
Bryan Hesskamp
Relief Valve Pressure
260
260
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
08685b3c-25f3-4b96-bf58-835168cf04de
08685b3c-25f3-4b96-bf58-835168cf04de
Location
Investors Title Company
219 S CENTRAL AVE, CLAYTON, MO
Phone: (314) 721-4001
219 S CENTRAL AVE, CLAYTON, MO
Phone: (314) 721-4001
Owner
Investors Title Company
219 S CENTRAL AVE, CLAYTON, MO 63105-3505
219 S CENTRAL AVE, CLAYTON, MO 63105-3505
Billing
Attn: Investors Title Company
219 S CENTRAL AVE, CLAYTON, MO 63105-3505
219 S CENTRAL AVE, CLAYTON, MO 63105-3505
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Provide a permanent, non-combustible pit sump pump cover capable of supporting at least 200 lbs. | 7/1/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room door shall be self-locking. | 7/1/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Provide a current tested fire extinguisher in the machine room. | 7/1/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | All non-elevator related equipment or materials shall be removed from the machine room. | 7/1/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | No | No | Replace the missing cotter pit on the door closer rod, 2nd floor. | 7/1/2020 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)2 | No | Yes | Observed a relief pressure of 700 psi. This pressure exceeds last years pressure of 400. Repair and retest the relief pressure. | 7/1/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | Yes | Fluids are leaking from the jack head/plunger gripper area. Repair as needed. | 7/1/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove fluids from the pit. | 7/1/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Yes | No | The machine room door shall be self-locking. | 7/10/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Yes | No | A current tested fire extinguisher is required in the elevator machine room. | 7/10/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Yes | No | Remove the fluids from the pit. The pit shall be kept dry. | 7/10/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Lighting in the machine room shall be not less than 10 foot-candles at floor level. | 3/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.5 Code Data Plate | No | No | Install a code data plate. It shall read "Missouri Minimum". | 3/13/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the pit of oil. | 3/13/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | A permanent lighting fixture shall provide an illumination of not less than five foot-candles at the pit floor. | 3/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device. | 3/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher is out of date. | 3/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 3/13/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Remove abandoned electrical conduit at the rear of the hoistway. | 3/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Pipes conveying liquid, gas, or vapor that cross overhead of elevator equipment or come in close proximity of the equipment shall be guarded or guttered. This is in reference to the pipe behind and over the elevator controller. | 3/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | The machine room shall be cleaned. | 3/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. Expired 2019. Repeat violation | 3/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A code compliant MCP and all the on-site documentation required shall be provided in the machine room. No MCP or documentation present in room. Repeat violation. | 3/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Lighting in the machine room shall be not less than 10 foot candles at floor level. Repeat violation. | 3/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.5 Code Data Plate | No | No | Install a code data plate. It shall read "Missouri Minimum". Repeat violation. | 3/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Pipes conveying liquid, gas, or vapor that cross overhead of elevator equipment or come in close proximity of the equipment shall be guarded or guttered. This is in reference to the pipe behind and over the elevator controller. Repeat violation. | 3/13/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | A permanent lighting fixture shall provide an illumination of not less than five foot-candles at the pit floor. Repeat violation. | 3/13/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the pit of oil. Repeat violation. | 3/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device. Repeat violation. | 3/13/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/13/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current operating certificate is required in the machine room. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Current ABC type fire extinguisher required in the machine room. |