Inspection
Inspection Details
Equipment ID
16962
16962
Inspection Date
6/19/2018
6/19/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Ronald Edwards
Ronald Edwards
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
Location
Independence Center
2035 Independence Center Dr, Independence, MO
Phone: (816) 795-8602
2035 Independence Center Dr, Independence, MO
Phone: (816) 795-8602
Owner
Simon Property Group
115 W Washington, Indianapolis, IN 46204
115 W Washington, Indianapolis, IN 46204
Billing
Attn: Independence Center
2035 Independence Center Dr, , MO 64059
2035 Independence Center Dr, , MO 64059
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | both Handrails need to be replaced or repaired | 2/19/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.2.13 | No | No | Crackec an broken handrails | 6/11/2020 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | no cirt of operation displayed | 7/23/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | no current cirt. displayed | 7/23/2025 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | No | No | mcp is there but not being maintained | 7/23/2025 |
| A17.1-2016 : Elevators | 8.12 - Steps, step chains, and trusses | 8.6.8.13 | No | No | top end needs to be cleaned | 7/23/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | no current cirt posted | 7/23/2025 |
| A17.1-2016 : Elevators | 8.12 - Steps, step chains, and trusses | 8.6.8.13 | No | No | escalator interior needs to be cleaned dn. | 7/23/2025 |
| A17.1-2016 : Elevators | 8.12 - Steps, step chains, and trusses | 8.6.8.13 | Yes | No | need internal clean dn | 2/3/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | no current cirt displayed | 7/23/2025 |
| A17.1-2016 : Elevators | 8.12 - Steps, step chains, and trusses | 8.6.8.13 | No | No | unit needs internal clean dn.truess ,tracks ,pan | 7/23/2025 |
| A17.1-2016 : Elevators | 7.3 - Handrails | 8.6.8.1 | No | No | Right handrail needs to be replaced cracked | 7/23/2025 |
| A17.1-2016 : Elevators | 8.12 - Steps, step chains, and trusses | 8.6.8.15.12 | Yes | No | step chain needs to be replaced bad chain rollers | |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | no cirt displayed | 7/23/2025 |