Inspection
Inspection Details
Equipment ID
18212
18212
Inspection Date
8/28/2020
8/28/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
24
24
External ID
7b956ea8-4eed-4b0f-adad-1b176924dda0
7b956ea8-4eed-4b0f-adad-1b176924dda0
Location
Edge Lofts LLC
715 N 21ST ST, SAINT LOUIS, MO
Phone: (314) 776-6000
715 N 21ST ST, SAINT LOUIS, MO
Phone: (314) 776-6000
Owner
Attn: Edge Lofts Leasing Office
The Edge Lofts, LLC c/o ND&S Management
715 N. 21st, SAINT LOUIS, MO 63103
Phone: (314) 435-2400
Email: theedgelofts@ndconsulting.com
The Edge Lofts, LLC c/o ND&S Management
715 N. 21st, SAINT LOUIS, MO 63103
Phone: (314) 435-2400
Email: theedgelofts@ndconsulting.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Finish 5 year test - Reinspection Required | 3/11/2021 | ||
conversion | conversion | conversion - reinspect | x | Diameter loss due to rouging exceeds proposed criteria. Need to replace suspension means A17.2.3.23 within 90 days. | 2/5/2019 | |
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/11/2021 | ||
A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. | 3/11/2021 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The in car ADA telephone shall be operational. | 10/27/2020 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | A category 5 test is overdue. The last category 5 test was performed in 2012. A category 5 test shall be scheduled and performed. | 10/27/2020 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | The governor rope and suspension ropes shall have data tags installed. | 3/11/2021 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The in car ADA telephone shall be operational. | 11/25/2020 | |
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/11/2021 | ||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The category 5 test shall be completed. The following testing items remain: 1. The car buffer shall be tested with rated capacity at rated speed. 2. The counterweight buffer shall be tested at the rated speed. | 11/25/2020 | |
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/29/2022 | ||
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. | 3/29/2022 | ||
A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | x | The phase 2 key switch is the wrong hand, this shall be corrected. The switch shall be rotated clockwise to go from the "OFF" to "HOLD" to "ON" position. | 3/29/2022 | |
A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 3/29/2022 | ||
A17.1-1996 : Elevators | 2.14 - Code data plate | 215 | Install a code data plate. It shall read "A17.1-1996". | |||
A17.1-1996 : Elevators | 2.11 - Disconnecting Means and Control | 210.4 | The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device. | |||
A17.1-1996 : Elevators | 2.27 - Rope fastenings | 212 | Wedge rope socket is anchored incorrectly. When the steel wire rope has been seated in the wedge socket by the load on the rope, the wedge shall be visible, and at least two wire-rope retaining clips shall be provided to attach the termination side to the load-carrying side of the rope. The first clip shall be placed a maximum of 4 times the rope diameter above the socket, and the second clip shall be located within 8 times the rope diameter above the first clip. | |||
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | Light bulbs and tubes within the car shall be equipped with guards, be recessed, or be mounted above a drop ceiling to prevent accidental breakage. | |||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Clean the pit of oil, dirt, and debris. | |||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | Pit light does not work. | |||
A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.1 | Remove abandoned light and wiring at the top of the hoistway. | |||
A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | Up-to-date fire extinguisher is required in the machine room. |