Inspection
Inspection Details
Equipment ID
17286
17286
Inspection Date
9/4/2020
9/4/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Timothy Mayes
Timothy Mayes
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
eebd058d-1f22-4879-a454-fea6d98a8b2f
eebd058d-1f22-4879-a454-fea6d98a8b2f
Location
Victor Roberts Building
1408 N KINGSHIGHWAY BLVD, SAINT LOUIS, MO
Phone: (314) 367-4600
1408 N KINGSHIGHWAY BLVD, SAINT LOUIS, MO
Phone: (314) 367-4600
Owner
Attn: 913 Locust
Roberts Brothers Properties
1408 N KINGSHIGHWAY BLVD STE 300, SAINT LOUIS, MO 63113-1420
Roberts Brothers Properties
1408 N KINGSHIGHWAY BLVD STE 300, SAINT LOUIS, MO 63113-1420
Billing
Attn: Roberts Brothers Properties
Tynetta Hopson
1408 N KINGSHIGHWAY BLVD STE 300, SAINT LOUIS, MO 63113-1420
Tynetta Hopson
1408 N KINGSHIGHWAY BLVD STE 300, SAINT LOUIS, MO 63113-1420
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11.1.4(b)(2) Hydraulic elevators Placed out of Service | x | x | Elevator placed out of service because full load test was not done as planned. Call to Charles Brinkmann confirmed decision to do so. | 9/30/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | Enclose hoistway wall at basement level. | 10/27/2020 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)15 | Guard hoistway window. | 10/27/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone and emergency light do not work. | 10/27/2020 | |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Light ray active on fire recall. | 10/27/2020 | ||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light inoperative. | 10/27/2020 | ||
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Cab fire service light inoperative. Elevator remains out of service due to numerous issues. | 10/27/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | A written MCP shall be kept in the elevator machine room for each elevator | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the machine room | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency light & alarm in car shall work on auxiliary power. Re-inspection reuired | 3/23/2023 | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Repair non working lighting in machine room, possible bad bulbs | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide current fire extinguisher in machine room | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Re-fasten hoist rope drip pan on top of elevator cab | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be properly displayed in machine space | 12/28/2023 |