Inspection
Inspection Details
Equipment ID
21311
21311
Inspection Date
8/27/2020
8/27/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Brent Davis
Brent Davis
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
28
28
External ID
9ce67068-48ce-41fa-b912-bf6414c1d2d1
9ce67068-48ce-41fa-b912-bf6414c1d2d1
Location
Gotham Aparments
5904 ENRIGHT AVE, SAINT LOUIS, MO
Phone: (314) 863-1313
5904 ENRIGHT AVE, SAINT LOUIS, MO
Phone: (314) 863-1313
Owner
Attn: Gotham Building Master Tenant LLC
Gotham Building Master Tenant LLC
120 S. Central Ave, Ste 500, St. Louis, MO 63105
Phone: (314) 336-3368
Gotham Building Master Tenant LLC
120 S. Central Ave, Ste 500, St. Louis, MO 63105
Phone: (314) 336-3368
Billing
Attn: Gotham Apartments
Gotham Apartments
5904 Enright Ave, St. Louis, MO 63112
Phone: (314) 336-3368
Gotham Apartments
5904 Enright Ave, St. Louis, MO 63112
Phone: (314) 336-3368
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Phase II fire service does not work, doors will not close. Did not red tag - Repair by 2-9-20 | 8/27/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work. | 8/27/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide maintenance control program. | 9/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean pit. | 9/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.9 Cleaning of Car Tops | No | No | Clean car top. | 9/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 8.11.2.1.2(d) | No | No | Remove all non-elevator related equipment from machine room. | 9/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | No | No | Provide guards on lights to prevent accidental contact or breakage. | 9/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Provide correct type of (ABC) fire extinguisher in elevator machine room. | 9/24/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work on 110v emergency power or normal power | 6/29/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher is out of date and must be serviced. | 12/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. RE-inspection required | 11/23/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.11 Runby (Re-Inspection) | Yes | No | Only 3 inches of C measurement, needs shortening. Re-inspection required | 2/16/2024 |