Inspection
Inspection Details
Equipment ID
2852
2852
Inspection Date
9/16/2020
9/16/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Donald Brown
Donald Brown
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
25
25
External ID
8af8950e-14f3-4b31-bc81-f8400f0fcd9b
8af8950e-14f3-4b31-bc81-f8400f0fcd9b
Location
US Bank
415 FRANCIS ST, SAINT JOSEPH, MO
Phone: (816) 233-2000
415 FRANCIS ST, SAINT JOSEPH, MO
Phone: (816) 233-2000
Owner
Attn: US BANK
US BANK
3640 S NOLAND RD STE 200, INDEPENDENCE, MO 64055
Phone: (816) 521-3387
Email: sherri.mast@usbank.com
US BANK
3640 S NOLAND RD STE 200, INDEPENDENCE, MO 64055
Phone: (816) 521-3387
Email: sherri.mast@usbank.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Door does not open when door open button is pushed while elevator is on fire service phase 2 operation. | 9/16/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Exposed 110 volt wiring on door operator needs to be enclosed in metal raceway. | 9/21/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Insufficient car lighting inside the elevator. Car lighting needs to be a minimum of 5 foot candles of illumination. | 9/21/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Post firefighter operating instructions inside the elevator that comply with fire service features that the elevator was constructed to meet. Existing signage is incorrect. | 9/21/2022 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Install cover over exposed 110 volt wiring on car door control box. | 9/21/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate inside machine room | 9/21/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Test and log firefighter operation monthly | 9/21/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Test and log firefighter operation monthly | 9/20/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Elevator cab lighting is insufficient, less than 5 foot candles of illumination. | 9/20/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Braille plates next to car button #1, and on floor 1 entrance frame, need to have a star on them to designate 1 as the main fire landing. Remove star on LL car button, and on floor LL entrance frame. | 9/20/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Remove firefighter call cancel button from car operating panel. Firefighter operation on this elevator was not designed for call cancel feature. | 8/31/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state operating certificate in machine room. | 9/20/2022 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | REPLACE BAD HOIST ROPES | 7/30/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | PHONE IS NOT WORKING | 7/30/2025 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | HOIST ROPES ARE BAD AND NEED TO BE REPLACED |