Inspection
Inspection Details
Equipment ID
14583
14583
Inspection Date
9/25/2020
9/25/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
22
22
External ID
05ab2f07-b6a4-43f6-b60b-0a7b53993f22
05ab2f07-b6a4-43f6-b60b-0a7b53993f22
Location
The Lofts @ 2020 Washington
2020 WASHINGTON AVE, SAINT LOUIS, MO
Phone: (314) 994-7440
2020 WASHINGTON AVE, SAINT LOUIS, MO
Phone: (314) 994-7440
Owner
Attn: The Lofts at 2020 Washington C/O Rafco Properties
The Lofts at 2020 Washington C/O Rafco Properties
2020 WASHINGTON AVE, SAINT LOUIS, MO 63103
Phone: (000) 000-0000
The Lofts at 2020 Washington C/O Rafco Properties
2020 WASHINGTON AVE, SAINT LOUIS, MO 63103
Phone: (000) 000-0000
Billing
Attn: 2020 Washington
2020 Washington
7700 FORSYTH BLVD STE 100, CLAYTON, MO 63105
Phone: (314) 721-8427
Email: service@smithmgmt.com
2020 Washington
7700 FORSYTH BLVD STE 100, CLAYTON, MO 63105
Phone: (314) 721-8427
Email: service@smithmgmt.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit shall be clean & dry, pit has 10" of water in it | |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light is not working, needs repair | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Elevator cab phone does not work. Re-inspection required | 2/17/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | |
| MO Minimum : Elevators | (I) - Pits | (I)2 | Yes | No | All buffer stands & buffer springs in elevator pit are rusted, need to replace all buffer stands & buffer springs in elevator pit. Re-inspection required | 2/17/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Need to test car safeties with rated load at rated speed. Re-inspection required | 2/17/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Need to perform 125% of rated brake test. Re-inspection required | 2/17/2025 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Elevator phone does not work, possible phone line problem, needs repaired. Re-inspection required | 2/17/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Need to test car safeties with rated load at rated speed. Re-inspection required | 2/17/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Need to perform 125% of rated load brake test. Re-inspection required | 2/17/2025 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Elevator cab phone does not work, possible phone line issue, needs repaired. Re-inspection required | 4/10/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room |