Inspection
Inspection Details
Equipment ID
507
507
Inspection Date
10/7/2020
10/7/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Carl Switzer
Carl Switzer
Relief Valve Pressure
360
360
Slide
Governor Rope Pull
Door Closing Force
20F/24R
20F/24R
External ID
1b9e44cf-1c00-41d4-949c-fa9ce2c1ca79
1b9e44cf-1c00-41d4-949c-fa9ce2c1ca79
Location
The Oaks Apartments
321 HAMILTON ST, NEOSHO, MO
Phone: (417) 451-5303
321 HAMILTON ST, NEOSHO, MO
Phone: (417) 451-5303
Owner
Neosho Housing Authority
321 HAMILTON ST, NEOSHO, MO 64850-1864
321 HAMILTON ST, NEOSHO, MO 64850-1864
Billing
Attn: Neosho Housing Authority
321 HAMILTON ST, NEOSHO, MO 64850-1864
321 HAMILTON ST, NEOSHO, MO 64850-1864
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | no current cdertificate | 11/8/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Telephone not working--reinspect required | 8/30/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 1.6 telephone does not work | 7/9/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. | 8/6/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location (REINSPECTION within 30 days) | 1/18/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1)/106.1 Pit shall be kept dry. Investigate and repair water leak. | 8/6/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location (REINSPECTION within 30 days) | 1/18/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1)/106.1 Pit shall be kept dry. Investigate and repair water leak. (Pit dry 1/18/21) | 1/18/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | phone shall work | 10/22/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No MCP onsite. | 10/14/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | phone shall work | 10/22/2021 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1.1.6 Verification of Telephone Operability | Yes | No | 2.27.1.1.6(a)Emergency communications loss monitor shall work. (REINSPECTION REQUIRED) | 9/27/2022 |