Inspection
Inspection Details
Equipment ID
13583
13583
Inspection Date
6/6/2018
6/6/2018
Inspection Type
Reinspection
Reinspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
27c9a771-27d8-4fe4-aeea-89fd3ca5ee77
27c9a771-27d8-4fe4-aeea-89fd3ca5ee77
Location
Art Loft
1531 WASHINGTON AVE, SAINT LOUIS, MO
1531 WASHINGTON AVE, SAINT LOUIS, MO
Owner
Art Loft & Associates
1531 WASHINGTON AVE, SAINT LOUIS, MO 63103-1814
1531 WASHINGTON AVE, SAINT LOUIS, MO 63103-1814
Billing
Attn: Art Loft & Associates
1531 WASHINGTON AVE, SAINT LOUIS, MO 63103-1814
1531 WASHINGTON AVE, SAINT LOUIS, MO 63103-1814
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - red tag | Yes | Yes | Elevator would not remain at floor with 125% capacity. | 9/13/2018 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Properly secure and lock machine room gate. | 9/13/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lights shall be guarded. | 9/13/2018 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit light shall work. | 1/1/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | The hatch door unlocking pull chain box shall be lockable at the top and bottom floor. | 3/25/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | NEC 620 - Provide a permanent power source to the pit sump pump. | 1/1/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.19 - Guide rails fastening and equipment | 8.11.2.1.3(y) | No | No | Correct the excessive play between the car guides and the rails. | 1/1/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Sump pump hall be covered | 11/17/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit lighting shall be made permanent | 11/17/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room access shall be secured | 11/17/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Machine room shall have permanent and safe access | 11/17/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Maintenance records shall be kept in the machine room | 11/17/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 6/30/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Machine motor piping shall be secured | 11/17/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room shall have lighting in front of controller | 11/17/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Elevator electrical prints shall be kept in the machine room | 11/17/2022 |
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | No | No | Hoistway access boxes shall be made lockable | 11/17/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | Emergency exit shall be bolted down | 11/17/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light shall be made operable. Re-inspection required | 6/30/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Sump pump shall be covered | 11/17/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room access shall be secured | 11/17/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Machine room shall have permanent and safe access | 11/17/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A copy of the MCP shall be kept in the elevator machine room | 11/17/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall be made operable. Re-inspection required | 8/4/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room lighting in front of controller | 11/17/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Elevator electrical prints shall be kept in the machine room | 11/17/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | Yes | No | Sump pump shall be covered. Re-inspection required | 10/7/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | Yes | No | A copy of the MCP shall be kept in the machine room. Re-inspection required | 10/7/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is inoperable. Re-inspection required | 10/7/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Yes | No | Machine room lighting in front of controller shall be 10 ft candles. Re-inspection required | 10/7/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | Yes | No | Elevator electrical prints shall be kept in the machine room. Re-inspection required | 10/7/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide current year MCP. | 4/1/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 4/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Yes | No | Provide safe and convenient access to the elevator machine room, numerous lights out. Repair/replace as needed. | 9/7/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Yes | No | Provide safe and convenient access to the elevator machine room, drain pipe at shin level-relocate. | 9/7/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Yes | No | Provide code complaint fire extinguisher in the elevator machine room. | 9/7/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Need to properly secure & lock machine room gate | 4/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Maintenance records shall be kept in the machine room | 4/1/2024 |