Inspection
Inspection Details
Equipment ID
21606
21606
Inspection Date
10/5/2020
10/5/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Charles Sheriff
Charles Sheriff
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
15
15
External ID
9e368a13-5a8f-4eed-a71c-c3a3080e056a
9e368a13-5a8f-4eed-a71c-c3a3080e056a
Location
Lacassian Lofts
2200 LOCUST ST, SAINT LOUIS, MO
Phone: (314) 610-0363
2200 LOCUST ST, SAINT LOUIS, MO
Phone: (314) 610-0363
Owner
Attn: AH Realty Advisors
AH Realty Advisors
P O Box 771070, SAINT LOUIS, MO 63177
Phone: (314) 499-0517
AH Realty Advisors
P O Box 771070, SAINT LOUIS, MO 63177
Phone: (314) 499-0517
Billing
Attn: 2200 Loocust Bldg
AH Realty Advisors
2200 LOCUST ST, SAINT LOUIS, MO 63103
Phone: (314) 499-0517
Email: lisa@ahrealtyadvisors.com
AH Realty Advisors
2200 LOCUST ST, SAINT LOUIS, MO 63103
Phone: (314) 499-0517
Email: lisa@ahrealtyadvisors.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Written maintenance control program shall be kept on site for each elevator. | 12/20/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 12/20/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/10/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. | 12/20/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | No | No | The lighting in the overhead shall be functional. | 12/20/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.13 - Governor,overspeed switch and seal | 8.11.2.1.2(bb) | Yes | No | The remote governor tripping/reset means on the controller (means to test) shall be operational. | 1/21/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted near the elevator controller. | 2/5/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light shall be operational. The minimum illumination at the car threshold, with the door closed shall not be less and (a) 50lx (5fc) for passenger elevator. | 2/3/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | Yes | No | Hoistway lighting shall be operational. | 2/3/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergnecy light still does not work after re-inspection. | 3/2/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | Yes | No | Hoistway lighting is still not working after re-inspection. | 3/2/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | Yes | No | Hoistway lighting is still not working after re-inspection. | 4/29/2026 |