Inspection
Inspection Details
Equipment ID
11736
11736
Inspection Date
5/3/2017
5/3/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Relief Valve Pressure
320
320
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
Location
St. Louis Booth Manor
3131 Iowa Ave, St. Louis, MO
Phone: (314) 773-6760
3131 Iowa Ave, St. Louis, MO
Phone: (314) 773-6760
Owner
St. Louis Booth Manor Inc
3131 Iowa Ave, St. Louis, MO 63118
3131 Iowa Ave, St. Louis, MO 63118
Billing
Attn: St. Louis Booth Manor Inc
3131 Iowa Ave, , MO 63118
3131 Iowa Ave, , MO 63118
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Car Re levels, oil bleeding through check balve repair or replace machine room control valve. | 7/3/2018 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)4 | No | No | Control valve on hydraulic pump unit is leaking hydraulic fluid back into tank. Car sank 3" during 15 minute standing test. Repair and reinspect within THIRTY (30) days | 4/21/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide on-site maintenance control program. | 10/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide updated documents. | 3/14/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Provide testing of Phase I &II | 11/18/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Cylinder packing is worn and leaking, repair as needed. | 3/14/2024 |
| A17.1-2016 : Elevators | 11.6 - Temperature/Humidity | 2.7.9.2 | Yes | No | Post the temperature and humiodity range for the equipment in the machine room. | 12/9/2024 |
| A17.1-2016 : Elevators | 4.5 - Access to Hoistway | 2.12.7 | Yes | No | The bottom hoistway access switch does not operate. | 12/9/2024 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.2 Phase I Operation Recall by Initiating Device | Yes | Yes | Return to test all initiating devices. The alarm company did not have the code for the fire panel. | 12/9/2024 |
| A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 8.6.5.16.5 | Yes | No | 5 year overspeed valve testing is due. Reinspection required. |