Inspection
Inspection Details
Equipment ID
2887
2887
Inspection Date
10/16/2020
10/16/2020
Inspection Type
Reinspection
Reinspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
External ID
a7c5b36c-3989-43b5-baff-3d01d4ec4f04
a7c5b36c-3989-43b5-baff-3d01d4ec4f04
Location
Utah Pumping Station
100 UTAH ST, SAINT LOUIS, MO
Phone: (314) 772-3429
100 UTAH ST, SAINT LOUIS, MO
Phone: (314) 772-3429
Owner
Attn: Chilufya Kaoma
Metropolitan St. Louis Sewer District
1025 Grand Glaize Parkway, Valley Park, MO 63088
Phone: (636) 861-6763
Email: ckaoma@stlmsd.com
Metropolitan St. Louis Sewer District
1025 Grand Glaize Parkway, Valley Park, MO 63088
Phone: (636) 861-6763
Email: ckaoma@stlmsd.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Provide access to hoistway at top level | 8/21/2019 |
| conversion | conversion | n/a | No | No | Post current state certificate in machine space | 8/21/2019 |
| conversion | conversion | n/a | No | No | Repair phone in car | 8/21/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | Emergency phone does not work. | 4/22/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 10/16/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Maintenance records and electrical prints shall be provided. | 10/15/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)6 | No | Yes | Hoistway doors shall comply with A17.1 1978 | 10/16/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)9 | No | Yes | A car door or gate shall be at each entrance, at least 7' high and interlocks shall be provided. | 10/16/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | Controller access cover needs to be non-combustible material. | 10/15/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current operating certificate. | 10/15/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)6 | No | Yes | Hoistway doors shall comply with A17.1 1978. Red tagged until compliant. | 11/4/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)9 | Yes | Yes | Door or gate shall be at least 7" high from each landing and provided with interlocks. Red tagged elevator. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | Controller access cover needs to be non-combustible material. | 11/4/2020 |