Inspection
Inspection Details
Equipment ID
12088
12088
Inspection Date
10/30/2020
10/30/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Raymond Stidham
Raymond Stidham
Mechanic Name
Donald Brown
Donald Brown
Relief Valve Pressure
450
450
Slide
Governor Rope Pull
Door Closing Force
23
23
External ID
c315939a-7edf-47f3-b66b-c91b417a346b
c315939a-7edf-47f3-b66b-c91b417a346b
Location
LaQuinta Inn
2214 TANEY ST, N KANSAS CITY, MO
Phone: (816) 221-1200
2214 TANEY ST, N KANSAS CITY, MO
Phone: (816) 221-1200
Owner
Attn: LQ
LQ Management LLC
909 HIDDEN RDG STE 600, IRVING, TX 75038
Phone: (000) 000-0000
Email: laquinta.elevators@lerchbates.com
LQ Management LLC
909 HIDDEN RDG STE 600, IRVING, TX 75038
Phone: (000) 000-0000
Email: laquinta.elevators@lerchbates.com
Billing
Attn: LQ Elevator Management c/o Lerch Bates
LQ
9780 S MERIDIAN BLVD STE 450, ENGLEWOOD, CO 80112
Phone: (000) 000-0000
Email: laquinta.elevators@lerchbates.com
LQ
9780 S MERIDIAN BLVD STE 450, ENGLEWOOD, CO 80112
Phone: (000) 000-0000
Email: laquinta.elevators@lerchbates.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove sprinkler head from ceiling above controller, no heat detector or shunt trip present. | 8/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide an MCP in machine room to log maintenance, repairs, and inspections. | 8/1/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate in machine room. | 8/1/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Debris in pit. | 8/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Provide a 5 gallon pit jug in pit to collect leakage from jack packing. | 8/1/2023 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | No | No | Main line disconnect has broken component inside, replace disconnect switch in machine room. | 8/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Handrail missing in car. | 8/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Handrail loose in car. | 8/1/2023 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | Yes | No | Stop switch on car operating panel worn, and not legible. Replace | 8/23/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Position indicator on COP not displaying floor numbers. | 8/1/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | machine room door not self locking provide self looking door handle | 8/25/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | mach. room door lock defeatable | 10/24/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | no current cirt displayed | 10/24/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | phone not working not answered | 10/23/2023 |
| A17.1-2016 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.14.2 Hydraulic Cylinders and Pressure Piping | Yes | Yes | leak down test failed dropped 2 inches in 15 mins futher testing required no shutoff valve | 10/23/2023 |