Inspection
Inspection Details
Equipment ID
1122
1122
Inspection Date
7/26/2017
7/26/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Joseph Jensen
Joseph Jensen
Mechanic Name
Relief Valve Pressure
460
460
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
23
23
External ID
1122
1122
Location
JCK Library
415 E, Clark St., Warrensburg, MO
Phone: (660) 543-4964
415 E, Clark St., Warrensburg, MO
Phone: (660) 543-4964
Owner
University of Central Missouri
116 S, Clark St, Warrensburg, MO 64093
116 S, Clark St, Warrensburg, MO 64093
Billing
Attn: University of Central Missouri
116 S, Clark St, , MO 64093
116 S, Clark St, , MO 64093
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Emergency phone not working no dial tone | 9/17/2018 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)1 | No | No | elevator settling 2 1/2" in 15 min-shut machine room valve--no settling-oil leaking back thru control balve. Repair or replace | 9/17/2018 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certifiate in machine room | 8/28/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Oil tank lid ahould be modified to provide safe access by maintenance personnel to valve and pump and prevent damage to oil coolers. 120v outlet to power oil coolers on # 2 nonfunctional | 8/27/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 8/27/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | In case of fire don't use elevator signage needed | 9/3/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | In case of fire don't use elevator signage needed | 11/22/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | missing "in case of fire" sign at lobby | 11/22/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | No | No | door closing pressure above 30 lbs | 7/6/2026 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 3.26.10 | Yes | No | Emergency battery lowering not working. Batteries | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | MCP needed | |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Light bulb burnt out |