Inspection
Inspection Details
Equipment ID
12916
12916
Inspection Date
10/22/2020
10/22/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Bill Suedkamp
Bill Suedkamp
Relief Valve Pressure
Slide
TBD
TBD
Governor Rope Pull
150/Bail Type
150/Bail Type
Door Closing Force
NA
NA
External ID
14f55413-5ee8-4bf1-b2f8-dee1534337d0
14f55413-5ee8-4bf1-b2f8-dee1534337d0
Location
Ital-Grani
7900 VAN BUREN ST, SAINT LOUIS, MO
Phone: (314) 633-3807
7900 VAN BUREN ST, SAINT LOUIS, MO
Phone: (314) 633-3807
Owner
Attn: Italgrani USA/Italgrani Elvator co/US Durum Milling
Italgrani USA/Italgrani Elvator co/US Durum Milling
7900 VAN BUREN ST, SAINT LOUIS, MO 63111
Phone: (314) 638-1447
Email: accountspayable@italgraniusa.com
Italgrani USA/Italgrani Elvator co/US Durum Milling
7900 VAN BUREN ST, SAINT LOUIS, MO 63111
Phone: (314) 638-1447
Email: accountspayable@italgraniusa.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The in car emergency lighting shall work. | 10/22/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The in car emergency telephone shall work. | 10/22/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 7/2/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | Properly secure the emergency exit as specified by the code. | 7/2/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept dry. Remove fluids from the pit and provide means to prevent accumulation of ground water from entering the pit. | 7/2/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall work. | 7/2/2021 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)5 | Yes | Yes | The car safeties failed to operate the SOS switch. Unit Red Tagged. | 11/10/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Governor pull out and pull thru and 125% brake test have been completed. The remaining items of the category 5 test and the annual inspection still need to be performed. | 11/10/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | The covers are missing from the hoistway door interlocks on the 2nd and 3rd floors. | 7/2/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The alarm bell on the car top is weak and shall be repaired or replaced. | 7/22/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | Attach the escape hatch to the car and secure it so that it is only openable from the outside without the use of tools. | 7/2/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | There were no keys on-site to test fire service. Keys to activate fire service shall be kept on-site at all times and fire service shall be tested to complete the annual inspection. | 7/22/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The emergency light and alarm shall be tested to complete the annual inspection. | 7/22/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 7/27/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Replace faded Phase 2 fire service signage. | 8/19/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit light shall work. | 8/19/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Replace missing interlock covers (exposed live wiring). | 8/19/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency bell doesn't work. | 8/13/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Fire service operation shall be tested. Keys were not on-site to test fire service. | 8/13/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Fire service operation shall be tested. No keys on-site to test. | 8/5/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work. Appears to dial, no answer. | 8/5/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a non-combustible frame with a clear protective vision plate over it. | 9/29/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self-closing and self-locking. | 9/29/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Car top shall be kept free of excess debris, dirt, and lint. | 9/29/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work. (2nd Notice) | 9/29/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Fire service operation shall be functional. No keys on-site originally. (2nd Notice) | 9/29/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Fire service operation shall be functional. Maximum 14 days to correct violation or unit to be red tagged. | 10/14/2025 |