Inspection
Inspection Details
Equipment ID
17361
17361
Inspection Date
10/20/2020
10/20/2020
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Jerry Reasoner
Jerry Reasoner
Relief Valve Pressure
Slide
16"
16"
Governor Rope Pull
n/a
n/a
Door Closing Force
22
22
External ID
e27d6d7e-0339-4764-b196-274101a5bddd
e27d6d7e-0339-4764-b196-274101a5bddd
Location
Argosy Casino
777 NW ARGOSY PKWY, RIVERSIDE, MO
Phone: (816) 746-3588
777 NW ARGOSY PKWY, RIVERSIDE, MO
Phone: (816) 746-3588
Owner
Argosy Casino
777 NW ARGOSY PKWY, RIVERSIDE, MO 64150-1512
777 NW ARGOSY PKWY, RIVERSIDE, MO 64150-1512
Billing
Attn: Argosy Casino
777 NW ARGOSY PKWY, RIVERSIDE, MO 64150-1512
777 NW ARGOSY PKWY, RIVERSIDE, MO 64150-1512
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | the coated steel belt monitor is flashing error that says the belts need to be replaced | 7/27/2018 |
| conversion | conversion | n/a | No | No | the governor tail sheave switch is not mounted carrectly, the switch arm is not between the two tail sheave studs so it will not trip in both the up and down directions | 11/23/2025 |
| A17.1-1996 : Elevators | 3.26 - Broken rope, chain, or tape switch | 210.2(f) | Yes | No | hoist belt monitor is flashing error on one of the blets, the belts are rouged, the belt monitor has been bypassed alowing the car to run, repair the belt monitor and remove the bypass and clean the rouge off of the belts | 10/20/2020 |
| A17.1-2016 : Elevators | 3.23 - Suspension Means | 8.11.2.1.3(cc) | No | No | hoist belt monitor is flashing error that one of the hoist belts is failing. Check that the belts test good and repair the belt monitor or if the belt tests bad replace the hoist belts | 3/30/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(c) | No | No | the monthly fire service test log is to be posted in the machine room | 11/23/2025 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | the copy of the state operating certificate is to be updated every year with the current certificate and posted in the machine room | 11/23/2025 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3 | Yes | Yes | The door open button did not work on fire service phase 2 operation. did not red tag elevator because both of the elevators that service the parking garage failed to open the doors on fire service phase 2 | 3/30/2023 |
| A17.1-1996 : Elevators | 2.3 - Lighting and receptacles | 101.5a Lighting | No | No | machine room lights are not working, replace burnt out light bulbs or repair broken fixtures as needed | 11/23/2025 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | repair cab ceiling lights, one of the fixtures is not working | 11/23/2025 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Repair/Re-lamp in car lighting | 11/23/2025 |
| A17.1-1996 : Elevators | 2.3 - Lighting and receptacles | 101.5a Lighting | No | No | Repair overhead lighting | 11/23/2025 |
| A17.1-2016 : Elevators | 2.4 - Machine space | 8.6.1.6.5 Fire Extinguishers | No | No | Provide updated fire extinguisher | 11/23/2025 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Owner to keep updated monthly fire service log | 11/23/2025 |
| A17.1-2016 : Elevators | 2.5 - Housekeeping | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean the car top | 11/23/2025 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Keep the pit clean and free of dirt and debris | |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.6.4.19.3 | Yes | No | Repair/replace remote governor reset solenoid - 2.7.6.5: provide means for testing | 9/4/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Update expired fire extinguisher. Repeat violation 9/4/2025 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide updated PM log / Owner to update monthly fire service log. Repeat violation 9/4/2025 | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean car top & Clean debris from the pit |